PPS FORTRON® 1140L6 CELANESE USA
294
- Unit Price:US$ 7,602 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:76MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Glass fiber reinforced|High temperature resistance
- Application Areas:fibre|Bottle cap
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
SpecificHeatCapacity of Melt | 内部方法 | 1500 J/kg/°C | |
density | ISO 1183 | 1.65 g/cm³ | |
Shrinkage rate | ISO 2577 | 0.2-0.6 % | |
Specific volume | ASTM D792 | 0.625 cm³/g | |
density | ISO 1183 | 1.65 g/cm³ | |
melt mass-flow rate | ASTM D1238 | 19 g/10min | |
Shrinkage rate | ASTM D955 | 0.20-0.30 % | |
ASTM D955 | 0.50-0.70 % | ||
ISO 294-4 | 0.40-0.60 % | ||
ISO 294-4 | 0.20-0.60 % | ||
Water absorption rate | ISO 62 | 0.020 % | |
spiral flow length | 内部方法 | 21.5 | |
density | ASTM D792 | 1.60 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ASTM D785 | 100 | |
ISO 2039-2 | 100 |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
CSARating | CSAF-1 | A00 |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ISO 62 | 0.02 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 53 kJ/m² | |
ISO 179/1eU | 53 kJ/m² | ||
Charpy Notched Impact Strength | ISO 179/1eA | 10 kJ/m² | |
ISO 179/1eA | 10 kJ/m² | ||
Impact strength of cantilever beam gap | ISO 180/1A | 10 kJ/m² | |
ISO 180/1A | 10 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180/1U | 34 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ISO 178 | 285 Mpa | |
Flexural modulus | ISO 178 | 14500 Mpa | |
Tensile strain | ISO 527-2/1A/5 | 1.9 % | |
elongation | ASTM D638 | 2.0 % | |
tensile strength | ISO 527-2/1A/5 | 195 Mpa | |
ASTM D638 | 200 Mpa | ||
Tensile modulus | ISO 527-1 | 14700 Mpa | |
tensile strength | ISO 527-1 | 195 Mpa | |
elongation | ISO 527-1 | 1.9 % | |
Flexural modulus | ISO 178 | 14500 Mpa | |
bending strength | ISO 178 | 285 Mpa | |
Impact strength of cantilever beam gap | ISO 180/1A | 10 kJ/m² | |
Rockwell hardness | ISO 2039-2 | 100 M-scale | |
Tensile modulus | ISO 527-2/1A/1 | 14700 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | ASTM D257 | 1E+16 ohms·cm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 4 | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
dielectric strength | ASTM D149 | 15 KV/mm | |
IEC 60243-1 | 28 KV/mm | ||
dielectric constant | ASTM D150 | 3.50 | |
ASTM D150 | 3.50 | ||
relative permittivity | IEC 60250 | 4.10 | |
Dissipation Factor | ASTM D150 | 1E-03 | |
ASTM D150 | 1E-03 | ||
IEC 60250 | 2E-03 | ||
arc resistance | ASTM D495 | 134 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-1 | 270 °C | |
UL flame retardant rating | UL 94 | V-0 | |
melting temperature | ISO 11357-3 | 280 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 2.6E-05 cm/cm/°C | |
ISO 11359-2 | 4.2E-05 cm/cm/°C | ||
Heat distortion temperature | ASTM D648 | 280 °C | |
ASTM D648 | 265 °C | ||
ISO 75-2/A | 270 °C | ||
ISO 75-2/C | 215 °C | ||
Glass Transition Temperature | ISO 11357-2 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.