Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:--
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 切口1/4″ | ASTM D256 | 10 kg-cm/cm |
| Elongation at Break | ASTM D638 | 3.0 % | |
| tensile strength | ASTM D638 | 1275 kg/cm | |
| Bending modulus | ASTM D790 | 100000 kg/cm | |
| bending strength | ASTM D790 | 2000 kg/cm |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 18.6kg/cm | ASTM D648 | 227(247) °C |
| Flame resistance | 0.8mm | UL 94 | V-0 |
| Linear coefficient of thermal expansion | ASTM D696 | 2.0 | |
| Melting temperature | DSC | 255 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 24hr immersion | ASTM D570 | 0.05 % |
| Fiberglass content | Ash | 30 % | |
| Shrinkage rate | Across Flow,- | ASTM D955 | 0.4-1.1 % |
| Flow,- | ASTM D955 | 0.1-0.3 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dielectric strength | 2mm | ASTM D149 | >22 KV/mm |
| Dielectric constant | ASTM D150 | 3.8 60Hz | |
| Volume resistivity | ASTM D257 | >10 Ω | |
| Arc resistance | ASTM D495 | 100 sec | |
| Volume resistivity | ASTM D257 | >10 Ω-cm | |
| Induced positive connection | ASTM D150 | 0.011 60Hz |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.