PA66 Zytel® FR53G50HSLR DUPONT USA
146
- Unit Price:US$ 6,250 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:25MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Thermal stability|High temperature resistance|Glass fiber reinforced|Filler: Glass fiber reinforced material|50% filler by weight
- Application Areas:Food containers
- Color:--
- Grade:Enhanced level
Technical Data Sheet
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat Deflection Temperature | ISO 75-2/B | 254 °C | |
ISO 75-2/A | 234 °C | ||
melting temperature | ISO 11357-3 | 260 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 1.7E-05 cm/cm/°C | |
ISO 11359-2 | 1.9E-05 cm/cm/°C | ||
ISO 11359-2 | 5.9E-05 cm/cm/°C | ||
ISO 11359-2 | 5.9E-05 cm/cm/°C | ||
ISO 11359-2 | 9.5E-05 cm/cm/°C |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
burning rate | ISO 3795 | <100 mm/min | |
UL flame retardant rating | UL 94 | HB | |
UL 94 | HB | ||
IEC 60695-11-10,-20 | HB | ||
IEC 60695-11-10,-20 | HB | ||
Limiting Oxygen Index | ISO 4589-2 | 27 % | |
FMVSS flammability | FMVSS302 | B |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 65 kJ/m² | |
ISO 179/1eU | 95 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 16000 Mpa | |
tensile strength | ISO 527-2 | 250 Mpa | |
Tensile strain | ISO 527-2 | 2.8 % | |
Tensile creep modulus | ISO 899-1 | -- Mpa | |
ISO 899-1 | -- Mpa | ||
flexural modulus | ISO 178 | 15000 Mpa | |
bending strength | ISO 178 | 390 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
volume resistivity | IEC 60093 | 1E+15 ohms·cm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 1 |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
shrinkage rate | ISO 294-4 | 0.50 % | |
ISO 294-4 | 0.20 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.