Material Properties:Low warpage|Good forming performance|Glass fiber reinforced|enhance
Application Areas:Automotive sector
Color:--
Grade:Extrusion grade
Material Certification
UL
Technical Data Sheet
other
Test Condition
Test Method
Test Result
purpose
电气 电子应用领域 连接器 线圈骨架
characteristic
低翘曲性 耐磨性能良好 低粘度 流动性高 刚性高 耐化学性良好
impact performance
Test Condition
Test Method
Test Result
Suspended wall beam without notch impact strength
6.40 mm
ASTM D256
250 J/m
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
0.30 mm
UL 94
V-0
Extreme Oxygen Index
ISO 527-1
40 %
Solder resistance
Internal Method
300 °C
mechanical properties
Test Condition
Test Method
Test Result
Elongation at Break
ASTM D638/ISO 527
5.1 %
Bending modulus
ASTM D790/ISO 178
11800 kg/cm²(MPa)[Lb/in²]
bending strength
23°C
ASTM D790
158 Mpa
Bending modulus
23°C
ASTM D790
11800 Mpa
elongation
Break
ASTM D638
5.1 %
tensile strength
ASTM D638
157 Mpa
bending strength
ASTM D790/ISO 178
158 kg/cm²(MPa)[Lb/in²]
injection
Test Condition
Test Method
Test Result
drying temperature
130 °C
drying time
4.0 to 24 hr
Temperature at the rear of the barrel
280 to 320 °C
Temperature in the middle of the barrel
320 to 340 °C
Temperature at the front of the material cylinder
340 to 360 °C
Spray nozzle temperature
340 to 360 °C
Processing (melt) temperature
350 °C
Mold temperature
40 to 160 °C
Injection pressure
80.0 to 160 Mpa
Injection speed
中等偏快
Maintain pressure
20.0 to 40.0 Mpa
Back pressure
1.00 to 5.00 Mpa
Screw speed
50 to 100 rpm
thermal performance
Test Condition
Test Method
Test Result
Linear coefficient of thermal expansion
Across Flow : 150°C
Internal Method
8.5E-5 cm/cm/°C
Linear coefficient of thermal expansion
Flow : 150°C
Internal Method
2.0E-6 cm/cm/°C
Hot deformation temperature
HDT
ASTM D648/ISO 75
269 ℃(℉)
Hot deformation temperature
1.8 MPa, Unannealed
ASTM D648
269 °C
Physical properties
Test Condition
Test Method
Test Result
Water absorption rate
Saturation
ASTM D570
0.020 %
Shrinkage rate
Flow
Internal Method
0.20 %
Shrinkage rate
横向Flow
Internal Method
0.60 %
Water absorption rate
ASTM D570/ISO 62
0.020 %
density
ASTM D792/ISO 1183
1.67
Electrical performance
Test Condition
Test Method
Test Result
Compared to the anti leakage trace index
IEC 60112
PLC 3
Arc resistance
ASTM D495
124 sec
Dissipation factor
1.00 GHz
ASTM D150
4.0E-3
Dissipation factor
1 MHz
ASTM D150
0.026
Dielectric constant
1.00 GHz
ASTM D150
3.50
Dielectric constant
1 MHz
ASTM D150
3.80
Volume resistivity
ASTM D257
1.0E+15 ohms·cm
hardness
Test Condition
Test Method
Test Result
Rockwell hardness
R-Scale
ASTM D785
106
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.