PP SEETEC M560 LG CHEM KOREA
401
- Unit Price:US$ 1,710 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:38MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:UV resistance|High temperature resistance|Thermal stability
- Application Areas:Electronic field|Electrical field
- Color:--
- Grade:Injection grade
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| melt mass-flow rate | ASTM D-1238 | 27.0 | g/10min | |
| density | ASTM D-792 | 0.900 | g/cm³ | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D-638 | 310 | kg/cm2 |
| Bending modulus | ASTM D-790A | 14 | Mpa | |
| Impact strength of cantilever beam gap | ASTM D-256 | 7 | kg.cm/cm | |
| elongation | Break | ASTM D-638 | >200 | % |
| Rockwell hardness | ASTM D-785 | 95 | R scale | |
| Impact strength of cantilever beam gap | ASTM D-3029GC | 140 | Kg.cm | |
| Elongation at Break | ASTM D-638 | 10 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D-648 | 125 | °C |
| Vicat softening temperature | ASTM D-1525B | 152 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | ASTM D-955 | 1.5-1.8 | % |
| MD | ASTM D-955 | 1.5-1.8 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 94HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.