Material Properties:High mobility|Good demolding performance|Good forming performance
Application Areas:Thin walled products|lens|Optical data storage|Safety equipment|container
Color:--
Grade:Injection grade
Material Certification
UL
Technical Data Sheet
optical performance
Test Condition
Test Method
Test Result
transmissivity
2540 μm
ASTM D1003
88.0 %
turbidity
2540 μm
ASTM D1003
1.0 %
impact performance
Test Condition
Test Method
Test Result
Dart impact
23°C, Energy at Peak
ASTM D3763
54.0 J
Impact strength of cantilever beam gap
ASTM D1822
378 kJ/m²
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
1.1 mm
UL 94
V-2
mechanical properties
Test Condition
Test Method
Test Result
tensile strength
Yield
ASTM D638
62.0 Mpa
tensile strength
Break
ASTM D638
65.0 Mpa
elongation
Break
ASTM D638
120 %
Bending modulus
50.0 mm Span
ASTM D790
2300 Mpa
bending strength
Yield, 50.0 mm Span
ASTM D790
93.0 Mpa
injection
Test Condition
Test Method
Test Result
drying temperature
120 °C
drying time
3.0 to 4.0 hr
Suggested maximum moisture content
0.020 %
Suggested injection volume
40 to 60 %
Temperature at the rear of the barrel
250 to 270 °C
Temperature in the middle of the barrel
260 to 280 °C
Temperature at the front of the material cylinder
270 to 295 °C
Spray nozzle temperature
265 to 290 °C
Processing (melt) temperature
270 to 295 °C
Mold temperature
70 to 95 °C
Back pressure
0.300 to 0.700 Mpa
Screw speed
40 to 70 rpm
Exhaust hole depth
0.025 to 0.076 mm
thermal performance
Test Condition
Test Method
Test Result
Hot deformation temperature
1.8 MPa, Unannealed, 3.20 mm
ASTM D648
126 °C
RTI Elec
UL 746
130 °C
RTI Imp
UL 746
130 °C
RTI
UL 746
130 °C
Physical properties
Test Condition
Test Method
Test Result
melt mass-flow rate
300°C/1.2 kg
ASTM D1238
25 g/10 min
Shrinkage rate
3.20 mm,Flow
Internal Method
0.50 - 0.70 %
Electrical performance
Test Condition
Test Method
Test Result
Compared to the anti leakage trace index
UL 746
PLC 2
High arc combustion index
UL 746
PLC 1
High voltage arc tracing rate
UL 746
PLC 2
Hot wire ignition
UL 746
PLC 2
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.