Material Description
- Material Properties:Low warpage|Glass fiber reinforced
- Application Areas:Laptop case|Phone case|Home appliance components
- Color:--
- Grade:Injection grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Dart impact | 23°C, Total Energy | ASTM D3763 | 8.00 | J |
| 23°C, Energy at Peak | ASTM D3763 | 6.00 | J | |
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 640 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5 mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | Break, 50.0 mm Span | ASTM D790 | 189 | Mpa |
| Bending modulus | 50.0 mm Span | ASTM D790 | 6890 | Mpa |
| tensile strength | Break | ASTM D638 | 110 | Mpa |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| drying temperature | 120 | °C | ||
| drying time | 3.0 to 4.0 | hr | ||
| Suggested maximum moisture content | 0.020 | % | ||
| Suggested injection volume | 40 to 80 | % | ||
| Temperature at the rear of the barrel | 240 to 255 | °C | ||
| Temperature in the middle of the barrel | 245 to 260 | °C | ||
| Temperature at the front of the material cylinder | 250 to 265 | °C | ||
| Spray nozzle temperature | 245 to 260 | °C | ||
| Processing (melt) temperature | 250 to 265 | °C | ||
| Mold temperature | 65 to 90 | °C | ||
| Back pressure | 0.300 to 0.700 | Mpa | ||
| Screw speed | 50 to 80 | rpm | ||
| Exhaust hole depth | 0.025 to 0.038 | mm | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | UL 746 | 125 | °C | |
| RTI Imp | UL 746 | 110 | °C | |
| RTI Elec | UL 746 | 125 | °C | |
| Linear coefficient of thermal expansion | 60 to 138°C,Flow | ASTM E831 | 1.6E-5 | cm/cm/°C |
| -40 to 40°C,Flow | ASTM E831 | 2.3E-5 | cm/cm/°C | |
| Hot deformation temperature | 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 176 | °C |
| 0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Specific volume | ASTM D792 | 0.660 | cm³/g | |
| Shrinkage rate | Flow : 1.50 to 3.20 mm | Internal Method | 0.30 - 0.50 | % |
| Flow : 3.20 to 4.60 mm | Internal Method | 0.50 - 0.80 | % | |
| Across FlowFlow : 1.50 to 3.20 mm | Internal Method | 0.40 - 0.60 | % | |
| Across FlowFlow : 3.20 to 4.60 mm | Internal Method | 0.60 - 0.90 | % | |
| Water absorption rate | 24 hr | ASTM D570 | 0.060 | % |
| Outdoor applicability | UL 746C | f2 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| High arc combustion index | UL 746 | PLC 3 | ||
| Compared to the anti leakage trace index | UL 746 | PLC 4 | ||
| Arc resistance | ASTM D495 | PLC 6 | ||
| Dissipation factor | 1 MHz | ASTM D150 | 0.020 | |
| 100 Hz | ASTM D150 | 1.4E-3 | ||
| Dielectric constant | 1 MHz | ASTM D150 | 3.60 | |
| 100 Hz | ASTM D150 | 3.60 | ||
| Dielectric strength | 3.20 mm, in Air | ASTM D149 | 24 | KV/mm |
| 1.60 mm, in Oil | ASTM D149 | 29 | KV/mm | |
| Volume resistivity | ASTM D257 | 5.9E+16 | ohms·cm | |
| High voltage arc tracing rate | UL 746 | PLC 2 | ||
| Hot wire ignition | UL 746 | PLC 1 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 119 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.