Material Description
- Material Properties:Glass fiber reinforced|Thermal stability
- Application Areas:Home appliance components|Electronic and electrical components
- Color:--
- Grade:--
Technical Data Sheet
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 60 kJ/m² |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Flammability level | UL 94 | V-2 |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 12500 Mpa | |
tensile strength | Break | ISO 527-2 | 200 Mpa |
Tensile strain | Break | ISO 527-2 | 2.5 % |
Bending modulus | ISO 178 | 12500 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 290 °C |
1.8 MPa, Unannealed | ISO 75-2/A | 290 °C | |
Melting temperature | ISO 11357-3 | 295 °C | |
Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 3.5E-5 cm/cm/°C |
Across Flow | ISO 11359-2 | 4.0E-5 cm/cm/°C | |
RTI Elec | 0.75 mm | UL 746 | 65.0 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | 横向Flow | ISO 294-4 | 1.1 % |
Flow | ISO 294-4 | 0.40 % | |
Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 2.3 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | > 1.0E+15 ohms·cm | |
Dielectric strength | IEC 60243-1 | 33 KV/mm | |
Relative permittivity | 100 Hz | IEC 60250 | 4.80 |
1 MHz | IEC 60250 | 4.40 | |
Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.