PA66 Vydyne® R515NT ASCEND USA
475
- Unit Price:US$ 3,824 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:25MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Filler: Glass fiber reinforced material|15% filler by weight
- Application Areas:Engine parts|Power/Other Tools|Shell|Parts under the hood of a car
- Color:--
- Grade:Enhanced level
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 1.0 % | |
ISO 294-4 | 0.50 % | ||
Water absorption rate | ISO 62 | 1.0 % | |
ISO 62 | 2.2 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
UL 94 | HB | ||
UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 6600 Mpa | |
tensile strength | ISO 527-2 | 120 Mpa | |
Tensile strain | ISO 527-2 | 3.0 % | |
Flexural modulus | ISO 178 | 5900 Mpa | |
bending strength | ISO 178 | 170 Mpa | |
Poisson's ratio | ISO 527-2 | 0.40 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179 | 32 kJ/m² | |
ISO 179 | 39 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | 1E+13 ohms·cm | |
dielectric strength | IEC 60243 | 24 KV/mm | |
arc resistance | ASTM D495 | PLC 5 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
High arc combustion index (HAI) | UL 746 | PLC 0 | |
UL 746 | PLC 0 | ||
UL 746 | PLC 0 | ||
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 1 | |
Hot wire ignition (HWI) | UL 746 | PLC 4 | |
UL 746 | PLC 4 | ||
UL 746 | PLC 4 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Imp | UL 746 | 85.0 °C | |
UL 746 | 85.0 °C | ||
UL 746 | 105 °C | ||
RTI Str | UL 746 | 115 °C | |
UL 746 | 120 °C | ||
UL 746 | 120 °C | ||
Heat distortion temperature | ISO 75-2/B | 258 °C | |
ISO 75-2/A | 241 °C | ||
melting temperature | ISO 11357-3 | 260 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 3E-05 cm/cm/°C | |
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
RTI Elec | UL 746 | 120 °C | |
UL 746 | 120 °C | ||
UL 746 | 120 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.