PC/ABS CYCOLOY™ C2950-76701 SABIC INNOVATIVE SINGAPHORE
233
- Unit Price:US$ 2,247 /MT
- Packaging Specification:
- Supply Quantity:20MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|High mobility|High impact resistance|High temperature resistance|heat-resisting
- Application Areas:Electrical field|Electronic field|Household appliances|Household appliances|Automotive sector
- Color:--
- Grade:Injection grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Instrumented dart impact energy 23 ℃ (73 ℉) total energy | ASTM D3763 | 61 | J | |
| Instrumented dart impact energy -30 ℃ (-22 ℉) peak | ASTM D3763 | 54 | J | |
| Impact strength of cantilever beam gap | 23℃ | ASTM D256 | 534 | J/m |
| 30℃ | ASTM D256 | 160 | J/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 2.6 mm/ | ASTM D790 | 2650 | Mpa |
| bending strength | 2.6 mm/,Yield | ASTM D790 | 102 | Mpa |
| Elongation at Break | Type I, 50 | ASTM D638 | 40 | |
| tensile strength | Type I, 50,Yield | ASTM D638 | 62 | Mpa |
| thermal properties | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | ASTM C 177 | 0.2 | W/m-°C | |
| Linear coefficient of thermal expansion | -30°C to 3,Across Flow | ASTM E831 | 72 | E-6/°C |
| -30°C to 3,Flow | ASTM E831 | 72 | E-6/°C | |
| RTI Imp | UL 746B | 85 | °C | |
| RTI Elec | UL 746B | 85 | °C | |
| RTI Imp | UL 746B | 85 | °C | |
| Vicat softening temperature | Rate B/50 | ASTM D1525 | 85 | °C |
| combustion performance | Test Condition | Test Method | Test Result | Test Unit |
| Limiting Oxygen Index (LOI) | ASTM D 2863 | 32 | % | |
| UL fire rating 5VB | UL 94 | 2.49 | mm | |
| UL fire rating V | UL 94 | 1.5 | mm | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | flow, 3.2 | ASTM D570 | 0.4 | |
| Shrinkage rate | xflow, 3.2 | Internal | 0.4-0.6 | |
| flow, 3.2 | Internal | 0.4-0.8 | ||
| melt mass-flow rate | ASTM D1238 | 10 | g/10min | |
| Water absorption rate | 24 hours | ASTM D570 | 0.1 | |
| Electrical Property | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 100000000000000000 | ohm-cm | |
| Surface resistivity | ASTM D257 | 10000000000000000 | Ohm | |
| Dielectric constant | ASTM D 150 | 3 | ||
| ASTM D 150 | 3 | |||
| Dissipation factor | ASTM D 150 | 50 | E-4 | |
| ASTM D 150 | 49 | E-4 | ||
| Compared to the Leakage Traceability Index (CTI) | UL 746A | PLC_0 | ||
| Dielectric strength | in oil, 3.2 | ASTM D149 | 19.5 | kV/mm |
| Arc resistance | ASTM D495 | PLC_6 | ||
| High voltage arc tracing rate | UL 746A | PLC 2 | ||
| Hot wire ignition (HWI) | UL 746A | PLC_1 | ||
| High current arc ignition (HAI) | UL 746A | PLC_0 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Hardness (Rockwell R) | ASTM D785 | 123 | R |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.