PC Makrolon® 2807 550115 COVESTRO SHANGHAI
262
- Unit Price:US$ 1,942 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:100MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Weather resistance|UV resistance|Medium viscosity
- Application Areas:Electrical field|Electronic field|Automotive sector|Industrial components|currency
- Color:--
- Grade:--
Technical Data Sheet
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 115 Mpa |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Haze ratio | ISO 14782 | <0.80 % | |
transmissivity | ISO 13468-2 | 87.0 % | |
refractive index | ISO 489 | 1.586 | |
transmissivity | ISO 13468-2 | 89.0 % | |
ISO 13468-2 | 88.0 % | ||
ISO 13468-2 | 89.0 % |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Imp | UL 746 | 115 °C | |
RTI Str | UL 746 | 125 °C | |
vicat | ISO 306/B120 | 145 °C | |
ISO 306/B50 | 143 °C | ||
Glass Transition Temperature | ISO 11357-2 | 144 °C | |
Heat Deflection Temperature | ISO 75-2/A | 124 °C | |
ISO 75-2/B | 136 °C | ||
RTI Elec | UL 746 | 125 °C | |
thermal conductivity | ISO 8302 | 0.20 W/m/K | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
ISO 11359-2 | 6.5E-05 cm/cm/°C | ||
ball-indentation hardness | IEC 60695-10-2 | Pass |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
needle flame test | IEC 60695-11-5 | 1.0 min | |
IEC 60695-11-5 | 0.1 min | ||
IEC 60695-11-5 | 2.0 min | ||
IEC 60695-11-5 | 0.1 min | ||
GlowWireTest | EDFHN60E.02 | 750 °C | |
needle flame test | IEC 60695-11-5 | 1.0 min | |
UL flame retardant rating | UL 94 | HB | |
UL 94 | V-2 | ||
Burning wire flammability index | IEC 60695-2-12 | 850 °C | |
IEC 60695-2-12 | 850 °C | ||
IEC 60695-2-12 | 930 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 875 °C | |
IEC 60695-2-13 | 875 °C | ||
IEC 60695-2-13 | 875 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 28 % | |
needle flame test | IEC 60695-11-5 | 0.2 min | |
SelfIgnitionTemperature | ASTM D1929 | 550 °C | |
FlashIgnitionTemperature | ASTM D1929 | 480 °C | |
GlowWireTest | EDFHN60E.02 | 750 °C | |
Burning rate - US-FMVSS | ISO 3795 | passed | |
ApplicationofFlamefromSmallBurner-Method | DIN 53438-1,-3 | K1.F1 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile strain | ISO 527-2/50 | 6.1 % | |
ISO 527-2/50 | 130 % | ||
tensile strength | ISO 527-2/50 | 66.0 Mpa | |
Tensile creep modulus | ISO 899-1 | 1900 Mpa | |
ISO 899-1 | 2200 Mpa | ||
Nominal tensile fracture strain | ISO 527-2/50 | >50 % | |
tensile strength | ISO 527-2/50 | 70.0 Mpa | |
bending strength | ISO 178 | 74.0 Mpa | |
flexural modulus | ISO 178 | 2400 Mpa | |
bending strength | ISO 178 | 98.0 Mpa | |
Bending Strain | ISO 178 | 7.0 % | |
Tensile modulus | ISO 527-2/1 | 2400 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 7391 | 75 kJ/m² | |
ISO 7391 | 14 kJ/m² | ||
Impact strength of cantilever beam gap | ISO 7391 | 70 kJ/m² | |
ISO 7391 | 15 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
ISO 179/1eU | NoBreak | ||
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 5400 N | |
ISO 6603-2 | 6300 N | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 65.0 J | |
ISO 6603-2 | 60.0 J |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
Water Vapor Transmission Rate | ISO 15106-1 | 15 g/m²/24hr | |
GasPermeation | ISO 2556 | 16900 cm³/m²/bar/24hr | |
ISO 2556 | 650 cm³/m²/bar/24hr | ||
ISO 2556 | 2760 cm³/m²/bar/24hr | ||
ISO 2556 | 120 cm³/m²/bar/24hr | ||
ISO 2556 | 510 cm³/m²/bar/24hr | ||
ISO 2556 | 3800 cm³/m²/bar/24hr |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | 1E+16 ohms | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
dielectric strength | IEC 60243-1 | 34 KV/mm | |
relative permittivity | IEC 60250 | 3.10 | |
IEC 60250 | 3.00 | ||
Dissipation Factor | IEC 60250 | 5E-04 | |
IEC 60250 | 9E-03 | ||
volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 4 |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.20 g/cm³ | |
Water absorption rate | ISO 62 | 0.12 % | |
ISO 62 | 0.30 % | ||
shrinkage rate | ISO 294-4 | 0.65 % | |
ISO 294-4 | 0.70 % | ||
ISO 2577 | 0.60-0.80 % | ||
Melt volume flow rate | ISO 1133 | 9.00 cm3/10min | |
shrinkage rate | ISO 2577 | 0.60-0.80 % | |
Apparent density | ISO 60 | 0.66 g/cm³ | |
melt mass-flow rate | ISO 1133 | 10 g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.