Material Description
- Material Properties:Low viscosity|Weather resistance|UV resistance
- Application Areas:film|Wire and cable
- Color:--
- Grade:--
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTM D542 | 1.586 | ||
| transmissivity | 2540μm | ASTM D1003 | 88.0 | % |
| turbidity | 2540μm | ASTM D1003 | 1.0 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 800 | J/m |
| Dart impact | 23°C | ASTM D3029 | 169 | J |
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 3200 | J/m |
| Impact strength of cantilever beam gap | ASTM D1822 | 546 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.762mm | UL 94 | HB | |
| Extreme Oxygen Index | ASTM D2863 | 25 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 62.1 | Mpa |
| Break | ASTM D638 | 65.5 | Mpa | |
| elongation | Yield | ASTM D638 | 7.0 | % |
| bending strength | Yield,50.0mmSpan | ASTM D790 | 93.1 | Mpa |
| Bending modulus | 50.0mmSpan | ASTM D790 | 2340 | Mpa |
| elongation | Break | ASTM D638 | 110 | % |
| Taber abraser | 1000Cycles,1000g,CS-17Wheel | ASTM D1044 | 10.0 | mg |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | UL 746 | 130 | °C | |
| RTI Imp | UL 746 | 130 | °C | |
| RTI | UL 746 | 130 | °C | |
| thermal conductivity | ASTMC177 | 0.19 | W/m/K | |
| specific heat | ASTMC351 | 1260 | J/kg/°C | |
| Linear coefficient of thermal expansion | MD:-40to95°C | ASTME831 | 6.8E-05 | cm/cm/°C |
| Vicat softening temperature | ASTM D15256 | 154 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 132 | °C |
| 0.45MPa,Unannealed,6.40mm | ASTM D648 | 138 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | -- | ASTM D792 | 1.20 | g/cm³ |
| Water absorption rate | Equilibrium,100°C | ASTM D570 | 0.58 | % |
| Outdoor applicability | UL 746C | f1 | ||
| Water absorption rate | Equilibrium,23°C | ASTM D570 | 0.35 | % |
| 24hr | ASTM D570 | 0.15 | % | |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 | % |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 11 | g/10min |
| Specific volume | ASTM D792 | 0.835 | cm³/g | |
| density | -- | ASTM D792 | 1.19 | g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 2 | |
| Hot wire ignition | HWI | UL 746 | PLC 4 | |
| Volume resistivity | ASTM D257 | >1.0E+17 | ohms·cm | |
| Dielectric strength | 3.20mm,inAir | ASTM D149 | 15 | KV/mm |
| Dielectric constant | 50Hz | ASTM D150 | 3.17 | |
| 60Hz | ASTM D150 | 3.17 | ||
| High arc combustion index | HAI | UL 746 | PLC 1 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 | |
| Dissipation factor | 1MHz | ASTM D150 | 0.010 | |
| 60Hz | ASTM D150 | 9E-04 | ||
| 50Hz | ASTM D150 | 9E-04 | ||
| Dielectric constant | 1MHz | ASTM D150 | 2.96 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 118 | |
| M-Scale | ASTM D785 | 70 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.