PBT 301-G30F BRICI BEIJING
429
- Unit Price:US$ 2,140 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:100MT
- Delivery Terms:FOB
- Port of Loading :Tianjin port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Glass fiber reinforced|High rigidity|high strength|heat-resisting|This product has no precipitation|high strength|High rigidity|Good heat resistance and other characteristics
- Application Areas:Electrical field|Electronic field|Plastic connectors|Household fan blades|Industrial wind blade
- Color:--
- Grade:--
Material Certification
Technical Data Sheet
| processability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Spiral flow length | 33 | CM | ||
| Shrinkage rate | ISO 294-4 | 0.4-0.8 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | Notched | ISO 179(leA) | 9 | kJ/m² |
| Bending modulus | ISO 178 | 9.45*103 | Mpa | |
| bending strength | ISO 178 | 205 | Mpa | |
| elongation | Break | ISO 527 | 2.6 | % |
| tensile strength | ISO 527 | 125 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.82MPa | ISO 75f | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23℃,24hr | ISO 62 | 0.12 | % |
| density | ISO 1183 | 1.63 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| ash content | 30 | % | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 | ||
| Arc resistance | IEC 61621 | 60 | sec | |
| Dielectric strength | IEC 60243 | 31 | KV/m | |
| Volume resistivity | IEC 60093 | 1*1014 | Ω。m | |
| Dielectric loss | 106HZ,Tangent | IEC 60250 | 1.7*10-2 | |
| Dielectric constant | 106HZ | IEC 60250 | 3.4 | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0(0.8mm) |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.