Material Description
- Material Properties:Flame retardant|Filler: Glass fiber reinforced material|10%|Filler by weight
- Application Areas:Business equipment|Electronic field|Automotive sector|Electrical field|Electrical/Electronic Applications
- Color:--
- Grade:Flame retardant grade
Material Certification

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 3.20mm | ASTM D256 | 110 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | |
| 1.5mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 90.0 | Mpa | |
| Bending modulus | ASTM D790 | 3500 | Mpa | |
| elongation | Break | ASTM D638 | 6.0 | % |
| tensile strength | ASTM D638 | 60.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15252 | 103 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 90.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ASTM D955 | 0.20-0.40 | % |
| melt mass-flow rate | 220°C/10.0kg | ASTM D1238 | 18 | g/10min |
| density | ASTM D792 | 1.15 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| CSAFileNo | LS66457 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.