PA46 Stanyl® SF5030 BK DSM JAPAN
266
- Unit Price:US$ 4,896 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:50.1MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Thermal stability|Flame retardant
- Application Areas:Fitness equipment|Electronic and electrical components
- Color:--
- Grade:Flame retardant grade
Technical Data Sheet
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40 kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 13 kJ/m² |
-30°C | ISO 179/1eA | 12 kJ/m² |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Flammability level | UL 94 | V-0 | |
UL 94 | V-0 |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending modulus | ISO 178 | 11000 Mpa | |
Tensile strain | Break | ISO 527-2 | 1.9 % |
tensile strength | Break | ISO 527-2 | 170 Mpa |
Tensile modulus | ISO 527-2 | 12000 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Elec | 0.35 mm | UL 746 | 65.0 °C |
Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 4.5E-5 cm/cm/°C |
Flow | ISO 11359-2 | 2.0E-5 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 295 °C | |
Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 290 °C |
0.45 MPa, Unannealed | ISO 75-2/B | 290 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.6 % |
Shrinkage rate | Flow | ISO 294-4 | 0.40 % |
横向Flow | ISO 294-4 | 1.1 % | |
density | ISO 1183 | 1.68 g/cm³ |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 3 | |
Relative permittivity | 1 MHz | IEC 60250 | 4.00 |
100 Hz | IEC 60250 | 4.30 | |
Dielectric strength | IEC 60243-1 | 30 KV/mm | |
Volume resistivity | IEC 60093 | > 1.0E+15 ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.