PPSU RADEL® 22000 WH 6417 SOLVAY USA
407
- Unit Price:US$ 32,231 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:20MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Resistance to stress cracking|Thermal stability|High impact resistance
- Application Areas:Medical devices|Electrical applications|household electrical appliances
- Color:--
- Grade:--
Technical Data Sheet
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D1822 | 368 kJ/m² |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2690 Mpa | |
tensile strength | ASTM D638 | 77.2 Mpa | |
elongation | Yield | ASTM D638 | 6.7 % |
Break | ASTM D638 | 50 % | |
Bending modulus | ASTM D790 | 2760 Mpa | |
bending strength | Yield | ASTM D790 | 108 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Annealed,3.18mm | ASTM D648 | 197 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | 24hr | ASTM D570 | 0.30 % |
30天 | ASTM D570 | 0.90 % | |
melt mass-flow rate | 380°C/2.16kg | ASTM D1238 | 12 g/10min |
Shrinkage rate | MD | ASTM D955 | 0.70 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | ASTM D257 | >9.0E+15 ohms·cm | |
Dielectric strength | 3.18mm | ASTM D149 | 19 KV/mm |
Dielectric constant | 1MHz | ASTM D150 | 3.40 |
Dissipation factor | 1MHz | ASTM D150 | 8E-03 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.