plas

PPS LATILUB  K/30 LATI ITALY

207
  • Unit Price:US$ 5,219 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    31MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Filler: Carbon fiber reinforced material30% filler by weight
  • Application Areas:--
  • Color:--
  • Grade:Injection grade

Technical Data Sheet

thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B280 °C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A270 °C
Continuous use temperature225 °C
Vicat softening temperatureISO 306/B50255 °C
Linear coefficient of thermal expansionMD:30to100°CISO 11359-22E-06 cm/cm/°C
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating0.75mmUL 94V-0
UL flame retardant rating1.5mmUL 94V-0
UL flame retardant rating3.0mmUL 94V-0
Physical propertiesTest ConditionTest MethodTest Result
Shrinkage rateTD:2.00mmISO 294-40.15-0.25 %
Shrinkage rateMD:2.00mmISO 294-40.10-0.20 %
Water absorption rate23°C,24hrISO 620.050 %
Electrical performanceTest ConditionTest MethodTest Result
Surface resistivityASTM D2571E+02 ohms
Volume resistivityASTM D2571E+04 ohms·cm
mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulus23°CISO 527-2/125000 Mpa
Tensile modulus60°CISO 527-2/123500 Mpa
Tensile modulus90°CISO 527-2/121000 Mpa
Tensile modulus120°CISO 527-2/115000 Mpa
Tensile modulus150°CISO 527-2/111000 Mpa
tensile strengthBreak,23°CISO 527-2/5185 Mpa
tensile strengthBreak,60°CISO 527-2/5165 Mpa
tensile strengthBreak,90°CISO 527-2/5130 Mpa
tensile strengthBreak,120°CISO 527-2/585.0 Mpa
tensile strengthBreak,150°CISO 527-2/570.0 Mpa
Tensile strainBreak,23°CISO 527-2/50.80 %
Tensile strainBreak,60°CISO 527-2/50.90 %
Tensile strainBreak,90°CISO 527-2/51.3 %
Tensile strainBreak,120°CISO 527-2/51.6 %
Tensile strainBreak,150°CISO 527-2/51.8 %
impact performanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notch23°CISO 179/1eU25 kJ/m²
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.