plas

PA6 Amilan®  CM1014-V0 TORAY JAPAN

476
  • Unit Price:US$ 1,662 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    30MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details
  • Material Comparison:

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Low halogen content
  • Application Areas:--
  • Color:--
  • Grade:Flame retardant grade

Material Certification

UL

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest Result
Elongation at BreakASTM D638/ISO 52712 %
bending strengthASTM D790/ISO 1781150 kg/cm²(MPa)[Lb/in²]
Rockwell hardnessASTM D785120
Tensile modulusASTM D638/ISO 52735000 kg/cm²(MPa)[Lb/in²]
Rockwell hardnessR-标度 23℃ASTM D-785120
Izod Heng StrikeV-Notched1/2 23℃ASTM D-2564 kg·cm/cm
Bending modulus23℃ASTM D-79035000 kg/cm
bending strength23℃ASTM D-7901150 kg/cm
Elongation at Break23℃ASTM D-63812 %
Tensile and flexural strength23℃ASTM D-638800 kg/cm
thermal performanceTest ConditionTest MethodTest Result
Melting temperature225 ℃(℉)
Melting temperature差示扫描测热计DSC225 °C
Hot deformation temperature4.6kg/cmASTM D-648207 °C
Physical propertiesTest ConditionTest MethodTest Result
densityASTM D792/ISO 11831.18
Flame resistant grade1/64"UL 94V-0
Electrical performanceTest ConditionTest MethodTest Result
Dielectric constantASTM D150/IEC 602505.2
Compared to the Leakage Traceability Index (CTI)导热率,温度指标UL 746600 V
Arc resistance1/8ASTM D-495123
Dissipation factor10ASTM D-1500.08
Volume resistivityASTM D-25710 Ω·cm
Dielectric constant10ASTM D-1505.2
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.