POM LUCEL® N109-LD LG CHEM KOREA
331
- Unit Price:US$ 2,370 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:20.1MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Type: Unreinforced
- Application Areas:--
- Color:--
- Grade:Demoulding grade
Material Certification

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | ASTM D-570 | 0.22 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | ASTM D-638 | 70 | % | |
| Linear coefficient of thermal expansion | ASTM D-695 | 10×0.000001 | mm/mm/ºC | |
| tension | ASTM D-638 | 625 | kg/cm | |
| Squeezing coefficient | 静 | ASTM D-1894 | 0.12 | |
| 动 | ASTM D-1894 | 0.16 | ||
| Rockwell hardness | ASTM D-785 | 82 | M(R) | |
| Bending modulus | ASTM D-790 | 26500 | kg/cm | |
| Impact strength of cantilever beam gap | Notched | ASTM D-256 | 7.0 | kg.cm/cm |
| Unnotched | ASTM D-256 | 80.0 | kg.cm/cm | |
| bending strength | ASTM D-790 | 1000 | kg/cm | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 4.6kg/cm | ASTM D-648 | 160 | ºC |
| 18kg/cm | ASTM D-648 | 110 | ºC | |
| Combustibility | 1/32" | HB | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Taber wear resistance | ASTM D-1044 | 14 | mg/1000cycles | |
| Shrinkage rate | 18-22 | cm/cm×0.0001 | ||
| density | ASTM D-792 | 1.41 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | ASTM D-150 | 3.8 | ||
| Dielectric strength | ASTM D-149 | 24 | KV/mm | |
| Surface resistance | ASTM D-257 | 1×10 | Ω | |
| Induced positive connection | ASTM D-150 | 0.007 | ||
| Arc resistance | ASTM D-495 | 240 | sec | |
| Antibody accumulation | ASTM D-257 | 1×10 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.