PC/ABS CYCOLOY™ C3650-111 SABIC INNOVATIVE NANSHA
196
- Unit Price:US$ 4,589 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:30MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:High mobility|Aging resistance
- Application Areas:Shell|Electronic and electrical components
- Color:--
- Grade:Injection grade
Technical Data Sheet
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | R级 | ISO 2039-2 | 124 |
ball-indentation hardness | H358/30 | ISO 2039-1 | 113 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | MD:23到60°C | ISO 11359-2 | 8E-05 cm/cm/°C |
TD:-40到40°C | ASTME831 | 7.2E-05 cm/cm/°C | |
TD:23to60°C | ISO 11359-2 | 8E-05 cm/cm/°C | |
thermal conductivity | ISO 8302 | 0.20 W/m/K | |
RTI Elec | UL 746 | 60.0 °C | |
RTI Imp | UL 746 | 60.0 °C | |
RTI Str | UL 746 | 60.0 °C | |
Heat Deflection Temperature | 0.45MPa,未退火,3.20mm | ASTM D648 | 100 °C |
0.45MPa,Unannealed,100mmSpan | ISO 75-2/Be | 102 °C | |
1.8MPa,未退火,3.20mm | ASTM D648 | 88.9 °C | |
1.8MPa,Unannealed,100mmSpan | ISO 75-2/Ae | 91.0 °C | |
vicat | ASTM D152510 | 110 °C | |
-- | ISO 306/B50 | 108 °C | |
-- | ISO 306/B120 | 110 °C | |
Linear coefficient of thermal expansion | MD:-40到40°C | ASTME831 | 7.2E-05 cm/cm/°C |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | 1.5mm | UL 94 | V-0 |
2.5mm | UL 94 | 5VB | |
Limiting Oxygen Index | ISO 4589-2 | 37 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 13 kJ/m² |
23°C | ISO 179/1eA | 48 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 13 kJ/m² |
0°C | ISO 180/1A | 15 kJ/m² | |
23°C | ISO 180/1A | 45 kJ/m² | |
Dart impact | 23°C,TotalEnergy | ASTM D3763 | 65.0 J |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | >1.0E+15 ohms | |
volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
dielectric strength | 0.800mm,在油中 | IEC 60243-1 | 35 KV/mm |
1.60mm,在油中 | IEC 60243-1 | 25 KV/mm | |
3.20mm,在油中 | IEC 60243-1 | 17 KV/mm | |
relative permittivity | 50Hz | IEC 60250 | 2.80 |
60Hz | IEC 60250 | 2.80 | |
1MHz | IEC 60250 | 2.70 | |
Dissipation Factor | 50Hz | ASTM D150 | 6E-03 |
60Hz | ASTM D150 | 6E-03 | |
50Hz | IEC 60250 | 4E-03 | |
60Hz | IEC 60250 | 4E-03 | |
1MHz | IEC 60250 | 6E-03 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | 260°C/5.0kg | ASTM D1238 | 8.5 g/10min |
Melt volume flow rate | 260°C/5.0kg | ISO 1133 | 8.00 cm3/10min |
shrinkage rate | MD:3.20mm | 内部方法 | 0.40-0.60 % |
Water absorption rate | 饱和,23°C | ASTM D570 | 0.60 % |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2860 Mpa | |
ISO 527-2/1 | 2600 Mpa | ||
tensile strength | 屈服 | ASTM D638 | 64.8 Mpa |
屈服 | ISO 527-2/5 | 55.0 Mpa | |
屈服 | ISO 527-2/50 | 65.0 Mpa | |
flexural modulus | ISO 178 | 2700 Mpa | |
bending strength | ISO 178 | 100 Mpa | |
屈服,50.0mm跨距 | ASTM D790 | 101 Mpa | |
tensile strength | 断裂 | ASTM D638 | 51.0 Mpa |
断裂 | ISO 527-2/5 | 50.0 Mpa | |
断裂 | ISO 527-2/50 | 55.0 Mpa | |
elongation | 屈服 | ASTM D638 | 4.9 % |
Tensile strain | 屈服 | ISO 527-2/5 | 3.0 % |
屈服 | ISO 527-2/50 | 4.5 % | |
elongation | 断裂 | ASTM D638 | 35 % |
Tensile strain | 断裂 | ISO 527-2/5 | 55 % |
断裂 | ISO 527-2/50 | >50 % | |
flexural modulus | 50.0mm跨距 | ASTM D790 | 2690 Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.