PEEK VESTAKEEP®  4000G EVONIK GERMANY

402
  • Unit Price:US$ 83,360 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    31MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Semi crystallineChemical resistanceSelf extinguishinghigh viscosity
  • Application Areas:--
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

thermal performanceTest ConditionTest MethodTest Result
vicatISO 306/A335 °C
vicatISO 306/B305 °C
Melting temperature (DSC)ISO 3146340 °C
Linear coefficient of thermal expansionISO 11359-26E-04 cm/cm/°C
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Burning wire flammability indexIEC 60695-2-12960 °C
Hot filament ignition temperatureIEC 60695-2-13825 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-23500 Mpa
tensile strengthISO 527-296.0 Mpa
Tensile strainISO 527-25.0 %
Tensile strainISO 527-230 %
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA6.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Physical propertiesTest ConditionTest MethodTest Result
densityISO 11831.30 g/cm³
Melt volume flow rateISO 113311.0 cm3/10min
shrinkage rateISO 294-41.1 %
shrinkage rateISO 294-40.90 %
Electrical performanceTest ConditionTest MethodTest Result
relative permittivityIEC 602502.80
relative permittivityIEC 602502.80
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Surface ResistivityIEC 600931E+14 ohms
volume resistivityIEC 600931E+15 ohms·cm
dielectric strengthIEC 60243-116 KV/mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.