PC IUPILON™  GS2010MR2 MITSUBISHI THAILAND

334
  • Unit Price:US$ 3,530 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    10MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    Shenzhen Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Flame retardantenhanceFiller: Glass fiber reinforced material10%Filler by weight
  • Application Areas:Fiber grade
  • Color:--
  • Grade:Enhanced level

Technical Data Sheet

otherTest ConditionTest MethodTest ResultTest Unit
characteristic玻纤增强
impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 17955kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.75mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
bending strengthISO 178135Mpa
Bending modulusISO 1784000Mpa
Tensile strainBreakISO 527-22.9%
tensile strengthBreakISO 527-278.0Mpa
Tensile modulusISO 527-24500Mpa
bending strengthASTM D790/ISO 178130kg/cm²(MPa)[Lb/in²]
Bending modulusASTM D790/ISO 1783900kg/cm²(MPa)[Lb/in²]
Tensile modulusASTM D638/ISO 5274400kg/cm²(MPa)[Lb/in²]
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionTDISO 11359-26.7E-05cm/cm/°C
Linear coefficient of thermal expansionMDISO 11359-24E-05cm/cm/°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A140°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B145°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rateSaturation,23°CISO 620.14%
Shrinkage rateMD:3.20mm0.30-0.50%
Shrinkage rateTD:3.20mm0.40-0.60%
Melt Volume Flow Rate (MVR)300°C/1.2kgISO 11339.00cm3/10min
melt mass-flow rate300°C/1.2kgISO 113310g/10min
densityASTM D792/ISO 11831.27
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexCTIUL 746PLC 4
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Sourcing & Prices

Selling & Verification

Explore Materials

Price Index

+86 0755 27873515

Room 906, Global Digital Building, No. 9 Gaoxin Middle 3rd Road, Maling Community, Yuehai Subdistrict, Nanshan District, Shenzhen, Guangdong Province, China