PC Makrolon® 2207 901510 COVESTRO SHANGHAI
217
- Unit Price:US$ 4,948 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:35MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Low viscosity|Low flow
- Application Areas:Industrial applications|Automotive sector|Electronic field|Electrical field|currency
- Color:--
- Grade:--
Technical Data Sheet
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 116 Mpa |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
transmissivity | ISO 13468-2 | 87.0 % | |
Haze ratio | ISO 14782 | <0.80 % | |
transmissivity | ISO 13468-2 | 89.0 % | |
ISO 13468-2 | 88.0 % | ||
ISO 13468-2 | 89.0 % | ||
refractive index | ISO 489 | 1.586 |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/B120 | 145 °C | |
ISO 306/B50 | 143 °C | ||
Heat Deflection Temperature | ISO 75-2/B | 136 °C | |
ISO 75-2/A | 123 °C | ||
Glass Transition Temperature | ISO 11357-2 | 144 °C | |
RTI Str | UL 746 | 125 °C | |
RTI Imp | UL 746 | 115 °C | |
RTI Elec | UL 746 | 125 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
thermal conductivity | ISO 8302 | 0.20 W/m/K | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
ball-indentation hardness | IEC 60695-10-2 | Pass |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
UL 94 | V-2 | ||
Burning wire flammability index | IEC 60695-2-12 | 850 °C | |
IEC 60695-2-12 | 875 °C | ||
SelfIgnitionTemperature | ASTM D1929 | 550 °C | |
needle flame test | IEC 60695-11-5 | 0.2 min | |
IEC 60695-11-5 | 0.1 min | ||
IEC 60695-11-5 | 2.0 min | ||
IEC 60695-11-5 | 0.1 min | ||
IEC 60695-11-5 | 2.0 min | ||
IEC 60695-11-5 | 1.0 min | ||
Burning rate - US-FMVSS | ISO 3795 | passed | |
FlashIgnitionTemperature | ASTM D1929 | 480 °C | |
ApplicationofFlamefromSmallBurner-Method | DIN 53438-1,-3 | K1.F1 | |
Limiting Oxygen Index | ISO 4589-2 | 28 % | |
Hot filament ignition temperature | IEC 60695-2-13 | 875 °C | |
IEC 60695-2-13 | 875 °C | ||
IEC 60695-2-13 | 875 °C | ||
IEC 60695-2-13 | 875 °C | ||
Burning wire flammability index | IEC 60695-2-12 | 930 °C |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 7391 | 12 kJ/m² | |
ISO 7391 | 55 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
ISO 179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ISO 7391 | 12 kJ/m² | |
ISO 7391 | 55 kJ/m² | ||
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 4900 N | |
ISO 6603-2 | 5900 N | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 55.0 J | |
ISO 6603-2 | 60.0 J |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 2400 Mpa | |
tensile strength | ISO 527-2/50 | 65.0 Mpa | |
ISO 527-2/50 | 60.0 Mpa | ||
Tensile strain | ISO 527-2/50 | 6.0 % | |
ISO 527-2/50 | 120 % | ||
Nominal tensile fracture strain | ISO 527-2/50 | >50 % | |
Tensile creep modulus | ISO 899-1 | 2100 Mpa | |
ISO 899-1 | 1700 Mpa | ||
bending strength | ISO 178 | 74.0 Mpa | |
ISO 178 | 98.0 Mpa | ||
Bending Strain | ISO 178 | 7.0 % | |
flexural modulus | ISO 178 | 2350 Mpa |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
GasPermeation | ISO 2556 | 150 cm³/m²/bar/24hr | |
ISO 2556 | 3150 cm³/m²/bar/24hr | ||
ISO 2556 | 750 cm³/m²/bar/24hr | ||
ISO 2556 | 18900 cm³/m²/bar/24hr | ||
ISO 2556 | 4500 cm³/m²/bar/24hr | ||
Water Vapor Transmission Rate | ISO 15106-1 | 15 g/m²/24hr | |
GasPermeation | ISO 2556 | 630 cm³/m²/bar/24hr |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
Dissipation Factor | IEC 60250 | 5E-04 | |
IEC 60250 | 9E-03 | ||
relative permittivity | IEC 60250 | 3.00 | |
IEC 60250 | 3.10 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | IEC 60243-1 | 34 KV/mm | |
Surface Resistivity | IEC 60093 | 1E+16 ohms |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
shrinkage rate | ISO 294-4 | 0.65 % | |
ISO 294-4 | 0.65 % | ||
Water absorption rate | ISO 62 | 0.30 % | |
ISO 62 | 0.12 % | ||
Apparent density | ISO 60 | 0.66 g/cm³ | |
density | ISO 1183 | 1.19 g/cm³ | |
shrinkage rate | ISO 2577 | 0.50-0.70 % | |
ISO 2577 | 0.50-0.70 % | ||
Melt volume flow rate | ISO 1133 | 34.0 cm3/10min | |
melt mass-flow rate | ISO 1133 | 37 g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.