AS(SAN) KIBISAN®  PN-127H TAIWAN CHIMEI

597
  • Unit Price:US$ 2,136 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    63MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    Kaoshiung port, China
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:enhanceGlass fiber reinforcedChemical resistance
  • Application Areas:ShellToothbrush handleHousehold goods
  • Color:--
  • Grade:Injection grade

Material Certification

UL
MSDS
RoHS
TDS
TDS
UL
MSDS
RoHS
SVHC
Processing
Statement

Technical Data Sheet

otherTest ConditionTest MethodTest ResultTest Unit
characteristic耐化学性
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gapASTM D256/ISO 1791.9(0.35)kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 1792.2(0.42)kg·cm/cm(J/M)ft·lb/in
tensile strengthASTM D638/ISO 527780(11.100)kg/cm²(MPa)[Lb/in²]
elongationASTM D638/ISO 5277%
Rockwell hardnessASTM D785M-85
Bending modulusASTM D790/ISO 17837000(52000)kg/cm²(MPa)[Lb/in²]
bending strengthASTM D790/ISO 1781100(15.600)kg/cm²(MPa)[Lb/in²]
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Combustibility (rate)UL 941.6mmHB
Hot deformation temperatureHDTASTM D648/ISO 75103(217)℃(℉)
Hot deformation temperatureHDTASTM D648/ISO 7594(201)℃(℉)
Vicat softening temperatureASTM D1525/ISO R306107(224)℃(℉)
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D792/ISO 11831.06kg·cm/cm(J/M)ft·lb/in
melt mass-flow rateASTM D1238/ISO 11331.5g/10min
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.