
PC 4610-10 STYRON TAIWAN
8
Unit Price:$2200 USD/MT
- Packaging Specification:
- Supply Quantity:
- 31MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:transparent Middle flow Medium liquidity transparent Medium liquidity transparent
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Density/specific gravity | ASTM D-792 | 1200 | kg/m | |
Melt mass flow rate | 300℃/1.2kg | ASTM D-1238 | 10 | g/10min |
Shrinkage rate | ASTM D-955 | 0.005-0.007 | mm/mm | |
Flame retardancy | 3.2mm | UL 94 | V-0 | |
1.6mm | UL 94 | V-2 |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
elongation | Break | ASTM D-638 | 120 | % |
Bending modulus | ASTM D-790 | 2400 | Mpa | |
elongation at yield | ASTM D-638 | 6 | % | |
Cantilever beam without notch impact strength | 23℃ | ASTM D-256 | 未破裂 | |
Tensile fracture strength | ASTM D-638 | 66 | Mpa | |
Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 900 | J/m |
Tensile yield strength | ASTM D-638 | 61 | Mpa | |
bending strength | ASTM D-790 | 100 | Mpa | |
Tensile modulus | ASTM D-638 | 2240 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | Unannealed@1.82MPa | ASTM D-648 | 127 | °C |
Spherical indentation temperature | IEC 598-1 | >125 | °C | |
Linear thermal shrinkage rate | 50℃/hr,50n重 | ASTM D-1525 | 154 | °C |
Hot deformation temperature | Annealed@0.45MPa | ASTM D-648 | 144 | °C |
Annealed@1.82MPa | ASTM D-648 | 140 | °C |
Other performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Glow filament test | 2.0mm | IEC 695-2-1 | 960 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top