Technical Data Sheet
Material Description
- Material Properties:Chemical resistance Low moisture absorption Filler: Glass fiber reinf 33% filler by weight
- Application Areas:Shell Vehicle electronics currency Lawn and garden equipment Laptop case Industrial components Valves/valve components Metal substitution Industrial applications Thick wall accessories (c Phone Application in the automo Machine/mechanical compon Electrical/Electronic App Parts under the hood of a
- Color:--
- Grade:--
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | MD | ASTMD955 | 0.50 | % |
TD | ASTMD955 | 1.0 | % | |
Water absorption rate | 24hr | ASTMD570 | 0.29 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | ASTMD638 | 11700 | Mpa | |
elongation | Break,23°C | ISO527-2 | 2.6 | % |
Break,24°C | ISO527-2 | 4.3 | % | |
Break,150°C | ISO527-2 | 6.6 | % | |
Break,175°C | ISO527-2 | 6.6 | % | |
Bending modulus | ASTMD790 | 11000 | Mpa | |
Tensile modulus | 23°C | ISO527-2 | 12600 | Mpa |
100°C | ISO527-2 | 6830 | Mpa | |
150°C | ISO527-2 | 5310 | Mpa | |
175°C | ISO527-2 | 4830 | Mpa | |
tensile strength | ASTMD638 | 200 | Mpa | |
Break,23°C | ISO527-2 | 211 | Mpa | |
Break,24°C | ISO527-2 | 125 | Mpa | |
Break,150°C | ISO527-2 | 87.6 | Mpa | |
Break,175°C | ISO527-2 | 79.3 | Mpa | |
elongation | Break | ASTMD638 | 2.5 | % |
Bending modulus | 23°C | ISO178 | 10400 | Mpa |
100°C | ISO178 | 7170 | Mpa | |
150°C | ISO178 | 4620 | Mpa | |
175°C | ISO178 | 4210 | Mpa | |
bending strength | ASTMD790 | 290 | Mpa | |
Cantilever beam without notch impact strength | 23°C | ISO180/1U | 59 | kJ/m² |
bending strength | 23°C | ISO178 | 296 | Mpa |
100°C | ISO178 | 177 | Mpa | |
150°C | ISO178 | 111 | Mpa | |
175°C | ISO178 | 99.3 | Mpa | |
compressive strength | ASTMD695 | 179 | Mpa | |
shear strength | ASTMD732 | 89.6 | Mpa | |
Poisson's ratio | 7.58 | 0.41 | ||
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 67 | kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 0.45MPa,Annealed,3.20mm | ASTMD648 | 320 | °C |
1.8MPa,Unannealed | ISO75-2/A | 294 | °C | |
1.8MPa,Annealed,3.20mm | ASTMD648 | 300 | °C | |
Continuous use temperature | ASTMD3045 | 210 | °C | |
Melting temperature | ISO11357-3 | 327 | °C | |
ASTMD570 | 327 | °C | ||
Linear coefficient of thermal expansion | MD:0to100°C | ASTME831 | 2E-05 | cm/cm/°C |
MD:100to200°C | ASTME831 | 1.5E-05 | cm/cm/°C | |
TD:0to100°C | ASTME831 | 7.6E-05 | cm/cm/°C | |
TD:100to200°C | ASTME831 | 1.2E-04 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Volume resistivity | ASTMD257 | 2E+16 | ohms·cm | |
Dielectric strength | 1.60mm | ASTMD149 | 20 | KV/mm |
Dielectric constant | 60Hz | ASTMD150 | 3.80 | |
1MHz | ASTMD150 | 3.60 | ||
Dissipation factor | 60Hz | ASTMD150 | 4E-03 | |
1MHz | ASTMD150 | 0.012 | ||
Compared to the anti leakage trace index | CTI | UL746 | 600 | V |
High voltage arc tracing rate | HVTR | UL746 | 14.0 | mm/min |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Light transmittance | 1070nm:1.60mm | ASTMD1003 | >20 | % |
940nm:1.60mm | ASTMD1003 | >20 | % |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
FlameRating | 3.2mm | UL94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.