Material Description
Technical Data Sheet
Material Description
- Material Properties:Colorable|Weather resistance
- Application Areas:Electronic and electrical|Lawn garden equipment
- Color:--
- Grade:Injection grade
Technical Data Sheet
Physical | Test Condition | Test Method | Test Result |
---|---|---|---|
Melt Mass-Flow Rate | 220°C/10.0 kg | ASTM D1238 | 8.8 g/10 min |
260°C/5.0 kg | ASTM D1238 | 7.1 g/10 min | |
280°C/3.8 kg | ASTM D1238 | 7.2 g/10 min | |
Melt Volume flow Rate | 260°C/5.0 kg | ISO 1133 | 9.00 cm3/10min |
Modeling Shrinkage | 流动 2 | 内部方法 | 0.40 到 0.70 % |
流动 : 3.20 mm | 内部方法 | 0.40 到 0.70 % | |
横向流动 : 3.20 mm | 内部方法 | 0.40 到 0.75 % | |
Moisture Absorption | 饱和, 23°C | ISO 62 | 0.50 % |
平衡, 23°C, 50% RH | ISO 62 | 0.20 % | |
Outdoor Suitability | UL 746C | f1 |
Thermal Properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Deflection Temperature Under Load? | 0.45 MPa, 未退火, 3.20 mm | ASTM D648 | 97.0 °C |
0.45 MPa, 未退火, 4.00 mm, 64.0 mm 跨距 11 | ISO 75-2/Bf | 98.0 °C | |
1.8 MPa, 未退火, 3.20 mm | ASTM D648 | 84.0 °C | |
1.8 MPa, 未退火, 4.00 mm, 64.0 mm 跨距 11 | ISO 75-2/Af | 84.0 °C | |
Vicat Softening Temperature | -- | 98.0 °C | |
-- | ISO 306/B50 | 95.0 °C | |
-- | ISO 306/B120 | 99.0 °C | |
Ball PressureTest | 83 到 87°C | IEC 60695-10-2 | 通过 |
Linear thermal expansion coefficient | 流动 : -40 到 40°C | ASTM E831 | 8.4E-5 cm/cm/°C |
流动 : -40 到 40°C | ISO 11359-2 | 8.3E-5 cm/cm/°C | |
横向 : -40 到 40°C | ASTM E831 | 9.4E-5 cm/cm/°C | |
横向 : -40°C | ISO 11359-2 | 9.4E-5 cm/cm/°C |
Optical | Test Condition | Test Method | Test Result |
---|---|---|---|
Gardner | 60°, 无织构 | ASTM D523 | 93 |
Flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | 1.5 mm | UL 94 | HB |
Mechanical Properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile Modulus | -- 3 | ASTM D638 | 2360 Mpa |
-- 4 | ASTM D638 | 2400 Mpa | |
-- | ISO 527-2/1 | 2350 Mpa | |
Tensile Strength | 屈服 5 | ASTM D638 | 46.0 Mpa |
屈服 6 | ASTM D638 | 43.0 Mpa | |
屈服 | ISO 527-2/50 | 45.0 Mpa | |
断裂 6 | ASTM D638 | 36.0 Mpa | |
断裂 5 | ASTM D638 | 37.0 Mpa | |
断裂 | ISO 527-2/50 | 36.0 Mpa | |
Tensile Elongation | 屈服 6 | ASTM D638 | 2.5 % |
屈服 5 | ASTM D638 | 2.7 % | |
屈服 | ISO 527-2/50 | 2.8 % | |
断裂 6 | ASTM D638 | 27 % | |
断裂 5 | ASTM D638 | 26 % | |
断裂 | ISO 527-2/50 | 36 % | |
Flexural Modulus | 50.0 mm 跨距 7 | ASTM D790 | 2450 Mpa |
-- 8 | ISO 178 | 2380 Mpa | |
Flexural Stress | -- 8, 9 | ISO 178 | 64.0 Mpa |
屈服, 50.0 mm 跨距 7 | ASTM D790 | 74.0 Mpa |
Injection | Test Condition | Test Method | Test Result |
---|---|---|---|
Drying Temperature | 85 到 90 °C | ||
Drying Time | 4.0 hr | ||
Suggested Max Moisture | 0.040 % | ||
Suggested Shot Size | 40 到 80 % | ||
Rear Temperature | 215 到 250 °C | ||
Middle Temperature | 220 到 255 °C | ||
Front Temperature | 230 到 260 °C | ||
Nozzle Temperature | 220 到 255 °C | ||
Processing (Melt) Temp | 240 到 270 °C | ||
Mold Temperature | 60 到 85 °C | ||
Back Pressure | 0.300 到 1.00 Mpa | ||
Screw Speed | 30 到 80 rpm | ||
Vent Depth | 0.038 到 0.076 mm |
Hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell Hardness | R 级 | ASTM D785 | 100 |
Impact Properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Instrumented Dart Impact | -30°C, Total Energy | ASTM D3763 | 3.00 J |
23°C, Total Energy | ASTM D3763 | 36.0 J |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.