TPE Hytrel® 4069 DUPONT USA
250
Unit Price:$12064 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 19MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Aging resistance Low temperature resistanc High temperature resistan
- Application Areas:Electrical appliances Automotive sector Electronic field Electrical field
- Color:--
- Grade:Extrusion grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
density | ISO1183 | 1.11 | g/cm³ | |
Melt mass flow rate | 220°C/2.16kg | ISO1133 | 8.5 | g/10min |
Melt Volume-Flow Rate (MVR) | 220°C/2.16kg | ISO1133 | 8.80 | cm3/10min |
Shrinkage rate | TD | ISO294-4 | 0.80 | % |
MD | ISO294-4 | 0.80 | % | |
Water absorption rate | 23°C,24hr | ISO62 | 0.70 | % |
Saturation,23°C,2.00mm | ISO62 | 0.70 | % | |
Equilibrium,23°C,2.00mm,50%RH | ISO62 | 0.30 | % | |
MediumDensity | 1.10 | g/cm³ |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | ISO527-2 | 45.0 | Mpa | |
tensile strength | Break | ISO527-2 | 29.0 | Mpa |
10%Strain | ISO527-2 | 3.20 | Mpa | |
50%Strain | ISO527-2 | 6.70 | Mpa | |
elongation | Break | ISO527-2 | >300 | % |
Nominal tensile fracture strain | ISO527-2 | 800 | % | |
Bending modulus | ISO178 | 45.0 | Mpa | |
Charpy Notched Impact Strength | -30°C | ISO179/1eA | NoBreak | |
23°C | ISO179/1eA | NoBreak | ||
Impact strength of simply supported beam without notch | -30°C | ISO179/1eU | NoBreak | |
23°C | ISO179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | -40°C | ISO180/1A | NoBreak | |
23°C | ISO180/1A | NoBreak | ||
Shore hardness | Shore D | ISO868 | 37 | |
Shore D,15sec | ISO868 | 33 | ||
Charpy Notched Impact Strength | -40°C | ISO179/1eA | NoBreak |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Brittle temperature | ISO974 | -96.0 | °C | |
Glass transition temperature | ISO11357-2 | -50.0 | °C | |
Linear coefficient of thermal expansion | TD:-40to23°C | ISO11359-2 | 2.8E-04 | cm/cm/°C |
TD:-- | ISO11359-2 | 2E-04 | cm/cm/°C | |
MD:-40to23°C | ISO11359-2 | 2.8E-04 | cm/cm/°C | |
MD:-- | ISO11359-2 | 2.2E-04 | cm/cm/°C | |
Melting temperature | ISO11357-3 | 193 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Relative permittivity | 100Hz | IEC60250 | 4.80 | |
1MHz | IEC60250 | 4.70 | ||
Dielectric strength | IEC60243-1 | 18 | KV/mm | |
Volume resistivity | IEC60093 | 4E+12 | ohms·cm | |
Surface resistivity | IEC60093 | 3E+14 | ohms | |
Dissipation factor | 100Hz | IEC60250 | 0.013 | |
1MHz | IEC60250 | 0.020 | ||
Leakage Trace Index | IEC60112 | 600 | V |
elastomer | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
tear strength | Across Flow | ISO34-1 | 100 | kN/m |
流量 | ISO34-1 | 100 | kN/m |
film | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
WaterVaporTransmission Rate | 23°C,85%RH,25µm | DIS15106-1/-2 | 900 | g/m²/24hr |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Burning rate | 1.00mm | ISO3795 | <100 | mm/min |
UL flame retardant rating | 1.5mm | UL94 | HB | |
3.0mm | UL94 | HB | ||
1.5mm | IEC60695-11-10,-20 | HB | ||
3.0mm | IEC60695-11-10,-20 | HB | ||
Extreme Oxygen Index | ISO4589-2 | 20 | % | |
FMVSS flammability | FMVSS302 | B |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Odor | VDA270 | 4.00 | ||
EmissionofOrganicCompounds | VDA277 | 10.0 | µgC/g |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top