PPS FORTRON® 1140L4 SF3001 CELANESE USA

277
Unit Price:$7256 USD/MT
Packaging Specification:
25 KG/PKG
Supply Quantity:
214MT
Delivery Terms:
FOB
Port of Loading:
China Main Port
Accepted Payment Methods:
T/T
Shipping:
Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Flame retardant High temperature resistan enhance Glass fiber reinforced Injection grade Medium melt viscosity
  • Application Areas:Fiber grade During injection molding Slight flash
  • Color:--
  • Grade:Flame retardant grade

Technical Data Sheet Compare

physical propertyTest ConditionTest MethodTest ResultUnit
Shrinkage rateTDISO294-40.40到0.60%
Shrinkage rateMDISO294-40.20到0.60%
Water absorption rateSaturation,23°CISO620.020%
Density/specific gravityISO 11831.65g/cm³
Water absorption rateASTM-D5700.02%
Shrinkage rateISO 294-40.2-0.6%
densityASTMD792,ISO11831.65g/cm³
Specific volumeASTMD7920.611cm³/g
Shrinkage rateMDASTMD9550.20到0.30%
Shrinkage rateTDASTMD9550.50到0.70%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
tensile strengthISO 527195Mpa
Tensile modulusISO 52714700Mpa
bending strengthISO 178285Mpa
Bending modulusISO 17814500Mpa
Impact strength of cantilever beam gapISO 180/1A10kJ/m²
Rockwell hardnessASTM-D785100R-Scale
Rockwell hardnessM-ScaleASTMD785100
Rockwell hardnessM-SaleISO2039-2100
Tensile modulus-40°CASTMD63814500Mpa
Tensile modulus75°CASTMD63811900Mpa
Tensile modulus150°CASTMD6384270Mpa
Tensile modulus200°CASTMD6383240Mpa
Tensile modulus--ISO527-2/1A/114700Mpa
Impact strength of cantilever beam gap-30°CISO180/1A10kJ/m²
Impact strength of cantilever beam gap23°CISO180/1A10kJ/m²
Cantilever beam without notch impact strength23°CISO180/1U34kJ/m²
tensile strengthBreak,23°CASTMD638200Mpa
tensile strengthBreakISO527-2/1A/5195Mpa
elongationBreak,23°CASTMD6381.7%
elongationBreakISO527-2/1A/51.9%
Bending modulus23°CISO17814500Mpa
Bending stressISO178285Mpa
Charpy Notched Impact Strength-30°CISO179/1eA10kJ/m²
Charpy Notched Impact Strength23°CISO179/1eA10kJ/m²
Impact strength of simply supported beam without notch-30°CISO179/1eU53kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eU53kJ/m²
Thermal performanceTest ConditionTest MethodTest ResultUnit
Linear coefficient of thermal expansionTDISO11359-24.2E-05cm/cm/°C
Hot deformation temperature0.45MPa,AnnealedASTMD648280°C
Hot deformation temperature1.8MPa,UnannealedASTMD648265°C
Hot deformation temperature1.8MPa,UnannealedISO75-2/A270°C
Hot deformation temperature8.0MPa,UnannealedISO75-2/C215°C
Glass transition temperatureISO11357-290.0°C
Melting temperatureISO11357-3280°C
Linear coefficient of thermal expansionMDISO11359-22.6E-05cm/cm/°C
Hot deformation temperature1.80MpaISO 75-A270°C
Flame retardant gradeUL94V-0
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dissipation factor1MHzIEC602506.2E-03
Arc resistanceASTMD495134sec
Leakage Trace IndexIEC60112125V
Surface resistivityIEC60093>1.0E+15ohms
Volume resistivity--ASTMD2571E+16ohms·cm
Volume resistivity--IEC60093>1.0E+15ohms·cm
Dielectric strengthIEC60243-128KV/mm
Dielectric constant1kHzASTMD1503.50
Dielectric constant1MHzASTMD1503.50
Dielectric constant1MHzIEC602504.60
Dissipation factor1kHzASTMD1501E-03
Dissipation factor1MHzASTMD1501E-03
Filling analysisTest ConditionTest MethodTest ResultUnit
SpecificHeatCapacity of Melt内部方法1500J/kg/°C
Biochemical propertiesTest ConditionTest MethodTest ResultUnit
Filling amount40%
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating0.38mmUL94V-0
UL flame retardant rating1.5mmUL94V-0
UL flame retardant rating3.0mmUL945VA
Extreme Oxygen IndexISO4589-247%
Supplementary InformationTest ConditionTest MethodTest ResultUnit
SpecimensThickness Shrinkage内部方法3.18mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App