PPS LUVOCOM® 1301-8646 LEHVOSS Group
0
- ویژگیها:Filler Lehmann Germany
- کاربردها:Applications in medical nursing supplies textile applications electrical electronic applications engineering accessories business equipment and automotive fields
برگه داده فنی
| impact performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.0 kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 10 kJ/m² |
| mechanical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
|---|---|---|---|
| Bending modulus | ISO 178 | 14000 MPa | |
| bending strength | ISO 178 | 100 MPa | |
| Tensile modulus | ISO 527-2 | 16000 MPa | |
| tensile strength | Break | ISO 527-2 | 68.0 MPa |
| Tensile strain | Yield | ISO 527-2 | 0.80 % |
| Bending strain | ISO 178 | 1.0 % |
| thermal performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
|---|---|---|---|
| Continuous use temperature | UL 746B | 220 °C | |
| Maximum operating temperature | ShortTerm | 240 °C |
| Physical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
|---|---|---|---|
| density | ISO 1183 | 1.88 g/cm³ | |
| Shrinkage rate | DIN 16901 | 0.30to0.70 % | |
| Water absorption rate | 23°C,24hr | <0.050 % |
| Electrical performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
|---|---|---|---|
| Surface resistivity | IEC 60093 | >1.0E+12 ohms | |
| insulation resistance | IEC 60167 | >1.0E+12 ohms |
نکات مهم: Plas.com دادههای برگه فنی را از تولیدکنندگان مواد جمعآوری کرده است. Plas.com تمام تلاش خود را برای افزایش دقت دادهها انجام میدهد، اما هیچ مسئولیتی در قبال دادهها ندارد. اکیداً توصیه میشود که صحت دادهها را با تولیدکنندگان مواد تأیید کنید پیش از آنکه تصمیم نهایی بگیرید.