برگه داده فنی
physical property | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
density | 23°C | ISO 1183 | 1.18 g/cm³ |
melt mass-flow rate | 330℃,2.16kg330℃/2.16 kg | ISO 1133 | 46 g/10min |
Melt volume flow rate | 330℃,2.16 kg330℃/2.16 kg | ISO 1133 | 45 cm3/10min |
Shrinkage rate | TD:2.0 mmAcross Flow : 0.0787 in | ISO 294-4 | 0.75 % |
Shrinkage rate | MD:2.0 mmFlow : 0,0787 in | ISO 294-4 | 0.75 % |
Water absorption rate | 饱和,23℃饱和,23℃ | ISO 62 | 0.3 % |
Water absorption rate | 平衡,23℃,50% RH平衡,23℃,50% RH | ISO 62 | 0.12 % |
optical performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
refractive index | | ISO 489 | 1.578 |
transmittance | 1000 µm1000 µm | ISO 13468-2 | 89 % |
Supplementary Information | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
electrolytic corrosion | 23℃23℃ | IEC 60426 | A1 |
Impact resistance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Impact strength of simply supported beam without notch | -30℃-30°C | ISO 179/1eU | No Break |
Impact strength of simply supported beam without notch | 23℃23°C | ISO 179/1eU | No Break |
Mechanical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Tensile modulus | 23℃23℃ | ISO 527-1-2 | 2400 Mpa |
tensile strength | 屈服,23℃屈服,23℃ | ISO 527-2/50 | 68 Mpa |
Tensile strain | 屈服,23℃屈服,23℃ | ISO 527-2/50 | 6.2 % |
Nominal tensile fracture strain | 23℃23℃ | ISO 527-2/50 | > 50 % |
Flexural modulus | 23℃23℃3 | ISO 178 | 2400 Mpa |
bending strength | 23℃ | ISO 178 | 100 Mpa |
ball-indentation hardness | | ISO 2039-1 | 120 Mpa |
Electrical performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Surface Resistivity | | IEC 60093 | 10000000000000000 ohms |
Volume resistivity | 23℃23℃ | IEC 60093 | 100000000000000000 ohms·cm |
dielectric strength | 23 ℃,1 mm23℃,1.00 mm | IEC 60243-1 | 35 KV/mm |
relative permittivity | 23℃,100 Hz23°C, 100 Hz | IEC 60250 | 3 |
relative permittivity | 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 2.9 |
Dissipation Factor | 23℃,100 Hz23°C, 100 Hz | IEC 60250 | 0.001 |
Dissipation Factor | 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 0.009 |
Compared to the Leakage Tracking Index (CTI) | 解决方案 ASolution A | IEC 60112 | PLC 2 |
Compared to the Leakage Tracking Index (CTI) | 解决方案 BSolution B | IEC 60112 | PLC 4 |
UL flame retardant rating | 1.50 mm | UL 94 | HB |
UL flame retardant rating | 3.00 mm | UL 94 | HB |
Glow wire combustion index (GWFI) | 2.0 mm2.0 mm | IEC 60695-2-12 | 900 °C |
Limiting Oxygen Index | | ISO 4589-2 | 26 % |
Thermal performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Heat distortion temperature | 1.8 MPa,未退火1.8 MPa,未退火,HDT | ISO 75-2/A | 138 °C |
vicat | B120B120 | ISO 306/B120 | 158 °C |
Linear coefficient of thermal expansion | TD:23~55℃TD:23 到 55℃ | ISO 11359-2 | 0.000065 1/℃ |
Linear coefficient of thermal expansion | MD:23~55℃MD:23 到 55℃ | ISO 11359-2 | 0.000065 1/℃ |
Relative Heat Index (RTI) | 电气性能电气性能 | UL 746 | 140 °C |
Relative Heat Index (RTI) | 强度机械性能强度机械性能 | UL 746 | 140 °C |
Relative Heat Index (RTI) | 冲击机械性能冲击机械性能 | UL 746 | 130 °C |
نکات مهم: Plas.com دادههای برگه فنی را از تولیدکنندگان مواد جمعآوری کرده است. Plas.com تمام تلاش خود را برای افزایش دقت دادهها انجام میدهد، اما هیچ مسئولیتی در قبال دادهها ندارد. اکیداً توصیه میشود که صحت دادهها را با تولیدکنندگان مواد تأیید کنید پیش از آنکه تصمیم نهایی بگیرید.