برگه داده فنی
physical property | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
density | ISO 1183 | 1.24 g/cm³ | |
Shrinkage rate | TD:23°C,2.00mm | ISO 294-4 | 1.0 % |
MD:23°C,2.00mm | ISO 294-4 | 0.50 % | |
Water absorption rate | 23°C,24hr | ISO 62 | 1.0 % |
平衡,23°C,50%RH | ISO 62 | 2.2 % |
flammability | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
UL flame retardant rating | 0.75mm | UL 94 | HB |
1.5mm | UL 94 | HB | |
3.0mm | UL 94 | HB | |
Burning wire flammability index | 0.75mm | IEC 60695-2-12 | 675 °C |
1.5mm | IEC 60695-2-12 | 675 °C | |
3.0mm | IEC 60695-2-12 | 675 °C | |
Hot filament ignition temperature | 0.75mm | IEC 60695-2-13 | 700 °C |
1.5mm | IEC 60695-2-13 | 700 °C | |
3.0mm | IEC 60695-2-13 | 700 °C |
Mechanical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
bending strength | 23°C | ISO 178 | 170 MPa |
Tensile modulus | 23°C | ISO 527-2 | 6600 MPa |
tensile strength | 断裂,23°C | ISO 527-2 | 120 MPa |
Tensile strain | 断裂,23°C | ISO 527-2 | 3.0 % |
Flexural modulus | 23°C | ISO 178 | 5900 MPa |
Poisson's ratio | ISO 527-2 | 0.40 |
Impact resistance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
Impact strength of cantilever beam gap | 23°C | ISO 180 | 6.6 kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO 179 | 6.0 kJ/m² |
23°C | ISO 179 | 6.0 kJ/m² | |
Impact strength of simply supported beam without notch | -30°C | ISO 179 | 32 kJ/m² |
23°C | ISO 179 | 39 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180 | 5.7 kJ/m² |
Electrical performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
Hot wire ignition (HWI) | 0.75mm | UL 746 | PLC 4 |
1.5mm | UL 746 | PLC 3 | |
3.0mm | UL 746 | PLC 4 | |
High arc combustion index (HAI) | 0.75mm | UL 746 | PLC 0 |
1.5mm | UL 746 | PLC 0 | |
3.0mm | UL 746 | PLC 0 | |
High Voltage Arc Traceability Rate (HVTR) | HVTR | UL 746 | PLC 1 |
Volume resistivity | 0.750mm | IEC 60093 | 1E+13 ohms·cm |
dielectric strength | 1.00mm | IEC 60243 | 20 kV/mm |
arc resistance | 3.00mm | ASTM D495 | PLC6 |
Compared to the Leakage Tracking Index (CTI) | 3.00mm | IEC 60112 | PLC 2 |
Thermal performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|---|---|---|
RTI Imp | 1.5mm | UL 746 | 120 °C |
3.0mm | UL 746 | 120 °C | |
RTI Str | 0.75mm | UL 746 | 125 °C |
Hot deformation temperature (HDT) | 0.45MPa,未退火,HDT | ISO 75-2/B | 258 °C |
1.8MPa,未退火,HDT | ISO 75-2/A | 241 °C | |
melting temperature | ISO 11357-3 | 260 °C | |
线性热膨胀系数 | MD:23to55°C,2.00mm | ISO 11359-2 | 3E-05 cm/cm/°C |
TD:23to55°C,2.00mm | ISO 11359-2 | 1.1E-04 cm/cm/°C | |
RTI Elec | 0.75mm | UL 746 | 140 °C |
1.5mm | UL 746 | 140 °C | |
RTI Str | 1.5mm | UL 746 | 140 °C |
3.0mm | UL 746 | 140 °C | |
RTI Elec | 3.0mm | UL 746 | 140 °C |
RTI Imp | 0.75mm | UL 746 | 120 °C |