Impact strength of simply supported beam without notch
-30°C
ISO 179/1eU
65 kJ/m²
Impact strength of simply supported beam without notch
23°C
ISO 179/1eU
80 kJ/m²
Charpy Notched Impact Strength
23°C
ISO 179/1eA
12 kJ/m²
Charpy Notched Impact Strength
-30°C
ISO 179/1eA
11 kJ/m²
Impact strength of cantilever beam gap
-40°C
ISO 180/1A
11 kJ/m²
Impact strength of cantilever beam gap
23°C
ISO 180/1A
12 kJ/m²
flammability
شرایط آزمون
روش آزمون
نتیجه آزمون
Flammability level
UL 94
HB
Flammability level
UL 94
HB
mechanical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
Bending modulus
160°C
ISO 178
3900 Mpa
Bending modulus
120°C
ISO 178
4700 Mpa
Bending modulus
--
ISO 178
9000 Mpa
Tensile strain
Break, 200°C
ISO 527-2
7.5 %
Tensile strain
Break, 180°C
ISO 527-2
7.5 %
Tensile strain
Break, 160°C
ISO 527-2
7.5 %
Tensile strain
Break, 120°C
ISO 527-2
7.5 %
Tensile strain
Break
ISO 527-2
4.0 %
tensile strength
Break, 200°C
ISO 527-2
90.0 Mpa
tensile strength
Break, 180°C
ISO 527-2
95.0 Mpa
tensile strength
Break, 160°C
ISO 527-2
100 Mpa
tensile strength
Break, 120°C
ISO 527-2
110 Mpa
tensile strength
Break
ISO 527-2
210 Mpa
Tensile modulus
200°C
ISO 527-2
4000 Mpa
Tensile modulus
180°C
ISO 527-2
4400 Mpa
Tensile modulus
160°C
ISO 527-2
5000 Mpa
Tensile modulus
120°C
ISO 527-2
5500 Mpa
Tensile modulus
--
ISO 527-2
10000 Mpa
thermal performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Hot deformation temperature
0.45 MPa, Unannealed
ISO 75-2/B
290 °C
Hot deformation temperature
1.8 MPa, Unannealed
ISO 75-2/A
290 °C
Melting temperature
ISO 11357-3
295 °C
Linear coefficient of thermal expansion
Flow
ISO 11359-2
2.5E-5 cm/cm/°C
Linear coefficient of thermal expansion
Across Flow
ISO 11359-2
6.0E-5 cm/cm/°C
RTI Elec
0.8 mm
UL 746
65.0 °C
Thermal Index - 5000 hr
IEC 60216
152 °C
Physical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
Water absorption rate
Equilibrium, 23°C, 50% RH
ISO 62
2.6 %
Shrinkage rate
Flow
ISO 294-4
0.50 %
Shrinkage rate
横向Flow
ISO 294-4
1.3 %
density
ISO 1183
1.41 g/cm³
Electrical performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Volume resistivity
IEC 60093
1.0E+15 ohms·cm
Dielectric strength
IEC 60243-1
35 KV/mm
Relative permittivity
100 Hz
IEC 60250
4.40
Relative permittivity
1 MHz
IEC 60250
4.00
Compared to the anti leakage trace index
IEC 60112
PLC 1
نکات مهم: Plas.com دادههای برگه فنی را از تولیدکنندگان مواد جمعآوری کرده است. Plas.com تمام تلاش خود را برای افزایش دقت دادهها انجام میدهد، اما هیچ مسئولیتی در قبال دادهها ندارد. اکیداً توصیه میشود که صحت دادهها را با تولیدکنندگان مواد تأیید کنید پیش از آنکه تصمیم نهایی بگیرید.