زمینههای کاربرد:لوازم پزشکی|لوازم مراقبت|مواد غذایی غیر خاص
رنگ:--
درجه:درجه تزریق
برگه داده فنی
optical performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Refractive index
ASTM D542
1.586
transmissivity
2540 μm
ASTM D1003
88.0 %
turbidity
2540 μm
ASTM D1003
1.0 %
impact performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Suspended wall beam without notch impact strength
23°C
ASTM D4812
3200 J/m
Dart impact
23°C
ASTM D3029
169 J
Impact strength of cantilever beam gap
ASTM D1822
577 kJ/m²
flammability
شرایط آزمون
روش آزمون
نتیجه آزمون
UL flame retardant rating
1.5 mm
UL 94
HB
Extreme Oxygen Index
ASTM D2863
25 %
mechanical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
tensile strength
Yield
ASTM D638
62.0 Mpa
tensile strength
Break
ASTM D638
68.0 Mpa
elongation
Yield
ASTM D638
7.0 %
elongation
Break
ASTM D638
130 %
Bending modulus
50.0 mm Span
ASTM D790
2340 Mpa
bending strength
Yield, 50.0 mm Span
ASTM D790
97.0 Mpa
Taber abraser
1000 Cycles, 1000 g, CS-17 Wheel
ASTM D1044
10.0 mg
injection
شرایط آزمون
روش آزمون
نتیجه آزمون
drying temperature
120 °C
drying time
3.0 to 4.0 hr
Suggested maximum moisture content
0.020 %
Suggested injection volume
40 to 60 %
Temperature at the rear of the barrel
270 to 295 °C
Temperature in the middle of the barrel
280 to 305 °C
Temperature at the front of the material cylinder
295 to 315 °C
Spray nozzle temperature
290 to 310 °C
Processing (melt) temperature
295 to 315 °C
Mold temperature
70 to 95 °C
Back pressure
0.300 to 0.700 Mpa
Screw speed
40 to 70 rpm
Exhaust hole depth
0.025 to 0.076 mm
thermal performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Hot deformation temperature
0.45 MPa, Unannealed, 6.40 mm
ASTM D648
137 °C
Hot deformation temperature
1.8 MPa, Unannealed, 6.40 mm
ASTM D648
132 °C
Vicat softening temperature
ASTM D15255
154 °C
Linear coefficient of thermal expansion
-40 to 95°C,Flow
ASTM E831
6.8E-5 cm/cm/°C
specific heat
ASTM C351
1250 J/kg/°C
thermal conductivity
ASTM C177
0.19 W/m/K
RTI Elec
UL 746
130 °C
RTI Imp
UL 746
130 °C
RTI
UL 746
130 °C
Physical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
Specific volume
ASTM D792
0.830 cm³/g
melt mass-flow rate
300°C/1.2 kg
ASTM D1238
11 g/10 min
Shrinkage rate
3.20 mm,Flow
Internal Method
0.50 - 0.70 %
Water absorption rate
24 hr
ASTM D570
0.15 %
Water absorption rate
Equilibrium, 23°C
ASTM D570
0.35 %
Water absorption rate
Equilibrium, 100°C
ASTM D570
0.58 %
Electrical performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Volume resistivity
ASTM D257
> 1.0E+17 ohms·cm
Dielectric strength
3.20 mm, in Air
ASTM D149
15 KV/mm
Dielectric constant
60 Hz
ASTM D150
3.17
Dielectric constant
50 kHz
ASTM D150
3.17
Dielectric constant
1 MHz
ASTM D150
2.96
Dissipation factor
50 Hz
ASTM D150
9.0E-4
Dissipation factor
60 Hz
ASTM D150
9.0E-4
Dissipation factor
1 MHz
ASTM D150
0.010
Compared to the anti leakage trace index
UL 746
PLC 2
High arc combustion index
UL 746
PLC 1
High voltage arc tracing rate
UL 746
PLC 2
Hot wire ignition
UL 746
PLC 2
hardness
شرایط آزمون
روش آزمون
نتیجه آزمون
Rockwell hardness
M-Scale
ASTM D785
70
Rockwell hardness
R-Scale
ASTM D785
118
نکات مهم: Plas.com دادههای برگه فنی را از تولیدکنندگان مواد جمعآوری کرده است. Plas.com تمام تلاش خود را برای افزایش دقت دادهها انجام میدهد، اما هیچ مسئولیتی در قبال دادهها ندارد. اکیداً توصیه میشود که صحت دادهها را با تولیدکنندگان مواد تأیید کنید پیش از آنکه تصمیم نهایی بگیرید.