Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT DR51 SABIC INNOVATIVE US
VALOX™
Non specific food,Lawn equipment,Garden equipment,Industrial applications,Automotive External Parts,Electrical field,Electronic field,Architectural application field,Outdoor applications,Electrical appliances,Engine hood parts,Medical supplies,Nursing supplies,Plastic bag,Automotive interior parts,Casters,Aerospace Applications
Glass fiber reinforced,Electrical performance
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 118 |
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 191 °C |
| 0.45MPa,Unannealed,6.40mm | ASTM D648 | 210 °C | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 2.2E-05 cm/cm/°C |
| MD:60to138°C | ASTME831 | 2.2E-05 cm/cm/°C | |
| RTI Elec | UL 746 | 130 °C | |
| RTI Imp | UL 746 | 130 °C | |
| RTI Str | UL 746 | 140 °C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| Bending modulus | 50.0mmSpan | ASTM D790 | 4830 Mpa |
| bending strength | Break,50.0mmSpan | ASTM D790 | 145 Mpa |
| Tensile strain | Break | ASTM D638 | 5.0 % |
| tensile strength | Break | ASTM D638 | 93.1 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| Arc resistance | ASTM D495 | PLC 5 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 |
| Dielectric constant | 100Hz | ASTM D150 | 3.60 |
| 1MHz | ASTM D150 | 3.40 | |
| Dielectric strength | 3.20mm,inAir | ASTM D149 | 20 KV/mm |
| 1.60mm,in Oil | ASTM D149 | 23 KV/mm | |
| Dissipation factor | 1MHz | ASTM D150 | 0.020 |
| 100Hz | ASTM D150 | 2E-03 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 1 |
| Volume resistivity | ASTM D257 | 3.3E+16 ohms·cm |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| density | ASTM D792 | 1.41 g/cm³ | |
| Shrinkage rate | TD:--2 | Internal Method | 0.50-0.80 % |
| MD:--2 | Internal Method | 0.40-0.60 % | |
| MD:--3 | Internal Method | 0.60-0.90 % | |
| TD:--4 | Internal Method | 0.80-1.1 % | |
| Specific volume | ASTM D792 | 0.712 cm³/g | |
| Water absorption rate | 24hr | ASTM D570 | 0.070 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 53 J/m |
| 23°C | ASTM D4812 | 530 J/m |
| flammability | Test Condition | Test Method | SABIC INNOVATIVE US/DR51 |
|---|---|---|---|
| UL flame retardant rating | 0.70mm | UL 94 | HB |