Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density / Specific Gravity | | ASTM D792 | 1.25 | g/cm³ |
Melt Mass-Flow Rate | 300°C/1.2 kg | ASTM D1238 | 9.0 | g/10 min |
Modeling Shrinkage - Flow | 23°C, 3.20 mm, Injection | ASTM D955 | 0.20 到 0.40 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Yield, 23°C, 3.20 mm, Injection | ASTM D638 | 53.9 | Mpa |
Tensile Elongation | Break, 23°C, 3.20 mm, Injection | ASTM D638 | 15 | % |
Flexural Modulus | 23°C, 3.20 mm, Injection | ASTM D790 | 3330 | Mpa |
Flexural Strength | 23°C, 3.20 mm, Injection | ASTM D790 | 98.1 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load | 1.8 MPa, Unannealed, 6.40 mm, Injection | ASTM D648 | 137 | °C |
RTI Elec | | UL 746 | 80.0 | °C |
RTI Imp | | UL 746 | 80.0 | °C |
RTI | | UL 746 | 80.0 | °C |
Injection | Test Condition | Test Method | Test Result | Unit |
---|
Drying Temperature | | | 100 到 120 | °C |
Drying Time | | | 3.0 到 5.0 | hr |
Suggested Max Moisture | | | 0.020 | % |
Minimum Moisture Content | | | 0.020 | % |
Rear Temperature | | | 280 到 295 | °C |
Middle Temperature | | | 285 到 300 | °C |
Front Temperature | | | 290 到 305 | °C |
Nozzle Temperature | | | 290 到 305 | °C |
Processing (Melt) Temp | | | 295 到 310 | °C |
Mold Temperature | | | 90 到 110 | °C |
Back Pressure | | | 0.981 到 3.92 | Mpa |
Screw Speed | | | 40 到 70 | rpm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Izod Impact Strength | 23°C, 3.20 mm, Injection | ASTM D256 | 270 | J/m |
Hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | R-Scale, 23°C, Injection | ASTM D785 | 124 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 0.75 mm | UL 94 | HB | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.