Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Across Flow | ISO 294-4 | 1.2 | % |
Modeling Shrinkage | 流量 | ISO 294-4 | 0.30 | % |
Moisture Absorption | Equilibrium, 23°C, 50% RH | ISO 62 | 1.6 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | -- | ISO 527-2 | 12000 | Mpa |
Tensile Modulus | 120°C | ISO 527-2 | 7500 | Mpa |
Tensile Modulus | 160°C | ISO 527-2 | 5000 | Mpa |
Tensile Stress | Break | ISO 527-2 | 155 | Mpa |
Tensile Stress | Break, 120°C | ISO 527-2 | 100 | Mpa |
Tensile Stress | Break, 160°C | ISO 527-2 | 70.0 | Mpa |
Tensile Strain | Break | ISO 527-2 | 2.0 | % |
Tensile Strain | Break, 120°C | ISO 527-2 | 2.7 | % |
Tensile Strain | Break, 160°C | ISO 527-2 | 3.7 | % |
Flexural Modulus | | ISO 178 | 11500 | Mpa |
Flexural Stress | | ISO 178 | 245 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Heat Deflection Temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 305 | °C |
Melting Temperature | | ISO 11357-3 | 325 | °C |
Coefficient of Linear Thermal Expansion | Flow | ISO 11359-2 | 1.5E-5 3.0E-5 | cm/cm/°C |
Coefficient of Linear Thermal Expansion | Across Flow | ISO 11359-2 | 3.5E-5 7.0E-5 | cm/cm/°C |
RTI Elec | 0.35 mm | UL 746 | 140 | °C |
Thermal Index - 5000 hr | | IEC 60216 | 163 | °C |
Electrical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | IEC 60093 | > 1.0E+15 | ohms·cm |
Dielectric Strength | | IEC 60243-1 | 33 | KV/mm |
Relative Permittivity | 100 Hz | IEC 60250 | 4.20 | |
Relative Permittivity | 1 MHz | IEC 60250 | 3.90 | |
Relative Permittivity | 1.00 GHz | IEC 60250 | 3.90 | |
Relative Permittivity | 10.0 GHz | IEC 60250 | 3.90 | |
Comparative Tracking Index | | IEC 60112 | 600 | V |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Unnotched Impact Strength | 23°C | ISO 179/1eU | 50 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 0.200 mm | IEC 60695-11-10, -20 | V-0 | |
Flame Rating | 1.5 mm | IEC 60695-11-10, -20 | V-0 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.