Impact strength of simply supported beam without notch
23°C
ISO 179
15 kJ/m²
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
1.6mm
UL 94
V-0
Basic Performance
Test Condition
Test Method
Test Result
Water absorption rate
23℃,24hr
ISO 11443-A
0.02 %
mechanical properties
Test Condition
Test Method
Test Result
Rockwell hardness
ASTM D-785
122 R
Elongation at Break
23℃
ASTM D-638
1.6 %
Impact strength of cantilever beam gap
ASTM D-256
80 J/m
compressive strength
ASTM D-732
75
Bending modulus
23℃
ASTM D-790
15.7 GPa
Suspended wall beam without notch impact strength
ASTM D-256
15 KJ/m
tensile strength
ASTM D-638
120 Mpa
bending strength
23℃
ASTM D-790
145 Mpa
tensile strength
Yield,23°C
ISO 527-2
110 Mpa
Tensile strain
Break,23°C
ISO 527-2
0.80 %
Bending modulus
23°C
ISO 178
19500 Mpa
bending strength
23°C
ISO 178
195 Mpa
shear strength
23°C
JISK7214
75.0 Mpa
Friction coefficient
0.25
Taber abraser
1000Cycles
ISO 9352
70.0 mg
thermal performance
Test Condition
Test Method
Test Result
Hot deformation temperature
1.8MPa,Unannealed
ISO 75-2/A
260 °C
Melting temperature
ISO 11357-3
278 °C
Linear coefficient of thermal expansion
Flow
ASTM D-696
2.4
Linear coefficient of thermal expansion
垂直
ASTM D-696
2.9
Hot deformation temperature
1.82MPa
ASTM D-648
>260 °C
Melting temperature
DSC
278 °C
Linear coefficient of thermal expansion
MD
ISO 11359-2
2E-05 cm/cm/°C
Linear coefficient of thermal expansion
TD
ISO 11359-2
2.8E-05 cm/cm/°C
Physical properties
Test Condition
Test Method
Test Result
Shrinkage rate
垂直
TORAY
0.60 %
Friction coefficient
ASTM D-1894
0.25
Taber wear resistance
ASTM D-1044
70 mg/1000次
Shrinkage rate
Flow
TORAY
0.15 %
Shrinkage rate
TD:3.00mm2
Internal Method
0.60 %
Shrinkage rate
MD:3.00mm4
Internal Method
0.30 %
Water absorption rate
23°C,24hr
ISO 62
0.020 %
Electrical performance
Test Condition
Test Method
Test Result
Volume resistivity
ASTM D-257
10 Ω.m
Volume resistivity
IEC 60093
1E+08 ohms·cm
Dielectric strength
IEC 60243-1
6.0 KV/mm
hardness
Test Condition
Test Method
Test Result
Rockwell hardness
R-Scale
ISO 2039-2
122
Supplementary Information
Test Condition
Test Method
Test Result
BarFlowLength
320°C,1.00mm
Internal Method
8.00 CM
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.