  • Material Properties:Hydrolysis resistance
  • Application Areas:Electronic and electrical accessoriesAutomotive sector
  • Color:--
  • Grade:--

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulus1mm/minISO 527-2/1A2600 Mpa
Tensile stress50mm/min,YieldISO 527-2/1A60 Mpa
Tensile modulus50mm/min,YieldISO 527-2/1A6 %
Elongation at Break50mm/minISO 527-2/1A200 %
Bending modulus23℃ISO 1782500 Mpa
bending strength23℃ISO 17880 Mpa
Charpy Notched Impact Strength23℃ISO 179/1eUNB KJ/m
Charpy Notched Impact Strength23℃ISO 179/1eA7.0 KJ/m
Impact strength of cantilever beam gap23℃ISO 180/1A5.5 KJ/m
Rockwell hardnessISO 2039-272 M
thermal performanceTest ConditionTest MethodTest Result
Melting temperatureISO 11357-1225 °C
Glass transition temperatureISO 11357-160 °C
Hot deformation temperature1.8MpaISO 75-1/-250 °C
Hot deformation temperature0.45MpaISO 75-1/-2150 °C
Vicat softening temperatureISO 306185 °C
Linear coefficient of thermal expansionAcross FlowISO 11359-21.3 E-4/℃
Linear coefficient of thermal expansionAcross FlowISO 11359-20.88 E-4/℃
Physical propertiesTest ConditionTest MethodTest Result
densityISO 11831310 kg/m
Shrinkage rateISO 294-41.8-2.0 %
Water absorption rate23℃,SaturationISO 620.45 %
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityIEC 60093>1E13 ohm.m
Surface resistivityIEC 60093>1E15 Ohm
Compared to the Leakage Traceability Index (CTI)IEC 60112600
Volume resistivity100HzIEC 602504
Volume resistivity1MHzIEC 602503.2
Dielectric dissipation factor1MHzIEC 60250200 E-4
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.