PEI ULTEM™ HU1010 7H1D395 SABIC INNOVATIVE NANSHA
262
- Unit Price:US$ 20,742 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Middle flow|Biocompatibility|Steam sterilization
- Application Areas:Medical devices|Medical and nursing supplies
- Color:--
- Grade:Injection grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.0 kJ/m² |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.0 kJ/m² |
| 23°C | ISO 180/1A | 5.0 kJ/m² | |
| 3.20mm | ASTM D256 | 1200 J/m | |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 33.0 J |
| 23°C | ASTM D3029 | 33.9 J |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.75mm | UL 94 | V-0 |
| 3.0mm | UL 94 | 5VA | |
| Extreme Oxygen Index | ASTM D2863 | 44 % | |
| NBSSmokeDensity-Flaming,Ds,4min | ASTME662 | 2.00 | |
| UL flame retardant rating | 0.71mm | UL 94 | V-2 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ASTM D638 | 3580 Mpa | |
| ISO 527-2/1 | 3200 Mpa | ||
| tensile strength | Yield | ASTM D638 | 110 Mpa |
| Yield | ISO 527-2/5 | 105 Mpa | |
| Break | ASTM D638 | 105 Mpa | |
| elongation | Yield | ASTM D638 | 7.0 % |
| Tensile strain | Yield | ISO 527-2/5 | 6.0 % |
| elongation | Break | ASTM D638 | 60 % |
| Tensile strain | Break | ISO 527-2/5 | 60 % |
| Bending modulus | 100mmSpan4 | ASTM D790 | 3520 Mpa |
| 50.0mmSpan5 | ASTM D790 | 3420 Mpa | |
| ISO 178 | 3300 Mpa | ||
| bending strength | ISO 178 | 160 Mpa | |
| Yield,50.0mmSpan5 | ASTM D790 | 174 Mpa | |
| Yield,100mmSpan4 | ASTM D790 | 165 Mpa | |
| Taber abraser | 1000Cycles,1000g,CS-17Wheel | ASTM D1044 | 10.0 mg |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 207 °C |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 199 °C | |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 193 °C | |
| Vicat softening temperature | ASTM D152511 | 219 °C | |
| -- | ISO 306/B50 | 211 °C | |
| -- | ISO 306/B120 | 212 °C | |
| Linear coefficient of thermal expansion | MD:-20to150°C | ASTME831 | 5.6E-05 cm/cm/°C |
| MD:-40to40°C | ISO 11359-2 | 5E-05 cm/cm/°C | |
| TD:-40to40°C | ASTME831 | 5E-05 cm/cm/°C | |
| TD:-40to40°C | ISO 11359-2 | 5E-05 cm/cm/°C | |
| thermal conductivity | ASTMC177 | 0.22 W/m/K | |
| RTI Elec | UL 746 | 170 °C | |
| RTI Imp | UL 746 | 170 °C | |
| RTI Str | UL 746 | 170 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| melt mass-flow rate | 337°C/6.6kg | ASTM D1238 | 18 g/10min |
| Melt Volume Flow Rate (MVR) | 360°C/5.0kg | ISO 1133 | 25.0 cm3/10min |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 % |
| Water absorption rate | Saturation,23°C | ISO 62 | 1.3 % |
| Equilibrium,23°C | ASTM D570 | 1.3 % | |
| Equilibrium,23°C,50%RH | ISO 62 | 0.70 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D257 | 1E+17 ohms·cm | |
| Dielectric strength | 1.60mm,inAir | ASTM D149 | 33 KV/mm |
| 1.60mm,in Oil | ASTM D149 | 28 KV/mm | |
| Dielectric constant | 1kHz | ASTM D150 | 3.15 |
| Dissipation factor | 1kHz | ASTM D150 | 1.3E-03 |
| 2.45GHz | ASTM D150 | 2.5E-03 | |
| Arc resistance | ASTM D495 | PLC 5 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 |
| High arc combustion index | HAI | UL 746 | PLC 3 |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 2 |
| Hot wire ignition | HWI | UL 746 | PLC 1 |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | M-Scale | ASTM D785 | 109 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.