PA66 Ultramid® D3G7 BK 20560 BASF SHANGHAI
249
- Unit Price:US$ 3,780 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:52MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High rigidity|Heat aging|Filler: Glass fiber reinforced material
- Application Areas:Gear bearing|Automotive components|Air transportation industry
- Color:--
- Grade:Injection grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179 | 60 kJ/m² |
| 23°C | ISO 179 | 80 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | 23°C | ISO 527-2 | 11300 Mpa |
| 150°C | ISO 527-2 | 4200 Mpa | |
| tensile strength | Break,23°C | ISO 527-2 | 200 Mpa |
| Break,150°C | ISO 527-2 | 84.0 Mpa | |
| Tensile strain | Break,23°C | ISO 527-2 | 2.9 % |
| Break,150°C | ISO 527-2 | 6.7 % | |
| Bending modulus | 23°C | ISO 178 | 10600 Mpa |
| bending strength | 23°C | ISO 178 | 300 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 260 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 240 °C | |
| Melting temperature | ISO 3146 | 260 °C | |
| Linear coefficient of thermal expansion | MD | 1.4E-5to2.0E-5 cm/cm/°C | |
| TD | 8.0E-5to1.3E-4 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | TD | ISO 294-4 | 0.87 % |
| MD | ISO 294-4 | 0.30 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | IEC 60093 | 3E+14 ohms·cm | |
| Dielectric strength | IEC 60243-1 | 48 KV/mm | |
| Compared to the anti leakage trace index | IEC 60112 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.