PC LEXAN™ EXL9330-WH9A445 SABIC INNOVATIVE NANSHA
185
- Unit Price:US$ 4,588 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:33MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Toughening|UV resistance
- Application Areas:food|Thin walled products|Casters
- Color:--
- Grade:--
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 无断裂 |
| -30°C | ISO 179/1eU | 无断裂 | |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 75 kJ/m² |
| -30°C | ISO 179/1eA | 60 kJ/m² | |
| Impact strength of cantilever beam gap | 23°C, 6.40 mm | ASTM D256 | 640 J/m |
| 23°C8 | Internal Method | 1100 J/m | |
| 23°C | ASTM D256 | 800 J/m | |
| -50°C | ASTM D256 | 590 J/m | |
| -30°C | ASTM D256 | 680 J/m | |
| 23°C9 | ISO 180/1A | 70 kJ/m² | |
| -30°C9 | ISO 180/1A | 55 kJ/m² | |
| -30°C10 | ISO 180/4A | 65 kJ/m² | |
| 23°C10 | ISO 180/4A | 80 kJ/m² | |
| Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | 无断裂 |
| 23°C | ISO 180/1U | 无断裂 | |
| Dart impact | 23°C, Total Energy | ASTM D3763 | 52.0 J |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Burning wire flammability index | 1.0 mm | IEC 60695-2-12 | 960 °C |
| UL flame retardant rating | 3.0 mm | UL 94 | 5VA |
| Extreme Oxygen Index | ISO 4589-2 | 35 % | |
| Hot filament ignition temperature | 1.0 mm | IEC 60695-2-13 | 825 °C |
| UL flame retardant rating | 1.5 mm | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| elongation | Break3 | ASTM D638 | 130 % |
| Break | ISO 527-2/50 | 130 % | |
| Yield | ISO 527-2/50 | 6.0 % | |
| Yield3 | ASTM D638 | 6.0 % | |
| tensile strength | Break | ISO 527-2/50 | 60.0 Mpa |
| Break3 | ASTM D638 | 61.0 Mpa | |
| Yield | ISO 527-2/50 | 55.0 Mpa | |
| Yield3 | ASTM D638 | 58.0 Mpa | |
| Tensile modulus | -- | ISO 527-2/1 | 2100 Mpa |
| --2 | ASTM D638 | 2100 Mpa | |
| bending strength | Yield, 50.0 mm Span4 | ASTM D790 | 88.0 Mpa |
| --5,6 | ISO 178 | 85.0 Mpa | |
| Bending modulus | --5 | ISO 178 | 2200 Mpa |
| 50.0 mm Span4 | ASTM D790 | 2060 Mpa |
| injection | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Screw speed | 40 to 70 rpm | ||
| Exhaust hole depth | 0.025 to 0.076 mm | ||
| Processing (melt) temperature | 295 to 315 °C | ||
| Mold temperature | 70 to 95 °C | ||
| Back pressure | 0.300 to 0.700 Mpa | ||
| Spray nozzle temperature | 290 to 310 °C | ||
| Temperature at the front of the material cylinder | 295 to 315 °C | ||
| Temperature in the middle of the barrel | 280 to 305 °C | ||
| Temperature at the rear of the barrel | 215 to 295 °C | ||
| Suggested maximum moisture content | 0.020 % | ||
| Suggested injection volume | 40 to 60 % | ||
| drying temperature | 120 °C | ||
| drying time | 3.0 to 4.0 hr |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI | UL 746 | 120 °C | |
| RTI Imp | UL 746 | 115 °C | |
| Linear coefficient of thermal expansion | Across Flow : 23 to 80°C | ISO 11359-2 | 7.7E-5 cm/cm/°C |
| RTI Elec | UL 746 | 125 °C | |
| Linear coefficient of thermal expansion | Across Flow : -40 to 40°C | ASTM E831 | 6.7E-5 cm/cm/°C |
| Flow : 23 to 80°C | ISO 11359-2 | 7.2E-5 cm/cm/°C | |
| Flow : -40 to 40°C | ASTM E831 | 6.7E-5 cm/cm/°C | |
| Ball Pressure Test | 123 to 127°C | IEC 60695-10-2 | 通过 |
| Vicat softening temperature | -- | ISO 306/B50 | 140 °C |
| -- | ASTM D152512 | 142 °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed, 4.00 mm, 100 mm Span11 | ISO 75-2/Ae | 124 °C |
| 1.8 MPa, Unannealed, 3.20 mm | ASTM D648 | 120 °C | |
| 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 124 °C | |
| 0.45 MPa, Unannealed, 4.00 mm, 100 mm Span11 | ISO 75-2/Be | 135 °C | |
| 0.45 MPa, Unannealed, 3.20 mm | ASTM D648 | 134 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Melt Volume Flow Rate (MVR) | 300°C/1.2 kg | ISO 1133 | 9.00 cm3/10min |
| density | -- | ISO 1183 | 1.19 g/cm³ |
| melt mass-flow rate | 300°C/1.2 kg | ASTM D1238 | 10 g/10 min |
| density | -- | ASTM D792 | 1.18 g/cm³ |
| Outdoor applicability | UL 746C | f1 | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.15 % |
| Saturation, 23°C | ISO 62 | 0.35 % | |
| Shrinkage rate | Across FlowFlow : 3.20 mm | Internal Method | 0.40 - 0.80 % |
| Flow : 3.20 mm | Internal Method | 0.40 - 0.80 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot wire ignition | UL 746 | PLC 1 | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | |
| High arc combustion index | UL 746 | PLC 0 | |
| Dissipation factor | 60 Hz | IEC 60250 | 1.0E-3 |
| Compared to the anti leakage trace index | UL 746 | PLC 3 | |
| Dissipation factor | 50 Hz | IEC 60250 | 1.0E-3 |
| 1 MHz | ASTM D150 | 8.5E-3 | |
| 60 Hz | ASTM D150 | 2.4E-3 | |
| 50 Hz | ASTM D150 | 2.4E-3 | |
| Dielectric constant | 1 MHz | IEC 60250 | 2.70 |
| 60 Hz | IEC 60250 | 2.60 | |
| 50 Hz | IEC 60250 | 2.60 | |
| 1 MHz | ASTM D150 | 2.90 | |
| 50 kHz | ASTM D150 | 2.95 | |
| 60 Hz | ASTM D150 | 2.95 | |
| Dielectric strength | 3.20 mm, in Oil | IEC 60243-1 | 16 KV/mm |
| 3.20 mm, in Oil | ASTM D149 | 17 KV/mm | |
| Surface resistivity | IEC 60093 | > 1.0E+15 ohms | |
| Volume resistivity | IEC 60093 | > 1.0E+15 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Ball Pressure Test | H 358/30 | ISO 2039-1 | 90.0 Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.