
PBT VALOX™ 553-BK1006 SABIC INNOVATIVE US
265
- Unit Price:US$ 4,101 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:42MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Low warpage|Glass fiber reinforced
- Application Areas:Automotive External Parts|Construction field|Outdoor applications|Electrical appliances|Plastic bag|Automotive interior parts|Casters
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D4812 | 640 J/m |
| 23°C | ASTM D256 | 85 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.9mm | UL 94 | V-0 |
| 2.3mm | UL 94 | 5VA | |
| Extreme Oxygen Index | ASTM D2863 | 37 % |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | Break | ASTM D638 | 110 Mpa |
| Bending modulus | 50.0mmSpan | ASTM D790 | 9400 Mpa |
| bending strength | Break,50.0mmSpan | ASTM D790 | 179 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI Str | UL 746 | 125 °C | |
| RTI Imp | UL 746 | 110 °C | |
| RTI Elec | UL 746 | 125 °C | |
| Linear coefficient of thermal expansion | MD:60to138°C | ASTME831 | 2.2E-05 cm/cm/°C |
| MD:-40to40°C | ASTME831 | 2.2E-05 cm/cm/°C | |
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 160 °C |
| 0.45MPa,Unannealed,6.40mm | ASTM D648 | 204 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 24hr | ASTM D570 | 0.070 % |
| Shrinkage rate | TD:--4 | Internal Method | 0.60-0.90 % |
| TD:--3 | Internal Method | 0.40-0.60 % | |
| MD:--3 | Internal Method | 0.30-0.50 % | |
| MD:--2 | Internal Method | 0.50-0.80 % | |
| Specific volume | ASTM D792 | 0.640 cm³/g | |
| density | ASTM D792 | 1.59 g/cm³ | |
| Outdoor applicability | UL 746C | f1 |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 3 |
| High arc combustion index | HAI | UL 746 | PLC 3 |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 |
| Hot wire ignition | HWI | UL 746 | PLC 1 |
| Arc resistance | ASTM D495 | PLC6 | |
| Dissipation factor | 1MHz | ASTM D150 | 0.020 |
| 100Hz | ASTM D150 | 2E-03 | |
| Dielectric constant | 1MHz | ASTM D150 | 3.70 |
| 100Hz | ASTM D150 | 3.80 | |
| Dielectric strength | 3.20mm,inAir | ASTM D149 | 19 KV/mm |
| 1.60mm,in Oil | ASTM D149 | 26 KV/mm | |
| Volume resistivity | ASTM D257 | 4.3E+16 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 118 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.