PBT Ultradur® S 4090 G6 BASF GERMANY
265
- Unit Price:US$ 3,851 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:58MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Enhanced level
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 85 J/m |
| -40°C | ASTM D256 | 69 J/m | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 59 kJ/m² |
| -30°C | ISO 179 | 50 kJ/m² | |
| Charpy Notched Impact Strength | 23°C | ISO 179 | 9.0 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 3.0mm | UL 94 | HB |
| 0.69mm | UL 94 | HB | |
| 1.5mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | 23°C | ASTM D790 | 194 Mpa |
| Bending modulus | 23°C | ISO 178 | 8300 Mpa |
| 23°C | ASTM D790 | 8270 Mpa | |
| Tensile creep modulus | 1000hr | ISO 899-1 | 6700 Mpa |
| tensile strength | Break,23°C | ISO 527-2 | 125 Mpa |
| Break,80°C | ISO 527-2 | 79.0 Mpa | |
| Tensile modulus | 23°C | ISO 527-2 | 9700 Mpa |
| tensile strength | Break,23°C | ASTM D638 | 125 Mpa |
| Break,-40°C | ISO 527-2 | 195 Mpa | |
| Break,120°C | ISO 527-2 | 47.0 Mpa | |
| Break,150°C | ISO 527-2 | 35.0 Mpa | |
| elongation | Break,23°C | ASTM D638 | 2.2 % |
| Tensile strain | Break,-40°C | ISO 527-2 | 2.4 % |
| Break,23°C | ISO 527-2 | 2.2 % | |
| Break,80°C | ISO 527-2 | 3.6 % | |
| Break,120°C | ISO 527-2 | 5.9 % | |
| Break,150°C | ISO 527-2 | 4.8 % | |
| Tensile creep modulus | 1hr | ISO 899-1 | 7600 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI Elec | 1.5mm | UL 746 | 130 °C |
| 0.69mm | UL 746 | 130 °C | |
| Linear coefficient of thermal expansion | MD | 4E-05 cm/cm/°C | |
| Melting temperature | ISO 3146 | 223 °C | |
| ASTM D3418 | 223 °C | ||
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 175 °C |
| 1.8MPa,Unannealed | ASTM D648 | 177 °C | |
| 0.45MPa,Unannealed | ISO 75-2/B | 210 °C | |
| 0.45MPa,Unannealed | ASTM D648 | 210 °C | |
| RTI Imp | 0.69mm | UL 746 | 90.0 °C |
| RTI Elec | 3.0mm | UL 746 | 130 °C |
| RTI Str | 3.0mm | UL 746 | 130 °C |
| RTI Imp | 1.5mm | UL 746 | 90.0 °C |
| 3.0mm | UL 746 | 90.0 °C | |
| RTI Str | 0.69mm | UL 746 | 130 °C |
| 1.5mm | UL 746 | 130 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | MD | ISO 294-4 | 0.29 % |
| TD | ISO 294-4 | 0.75 % | |
| MD:3.18mm | 0.30 % | ||
| Water absorption rate | Saturation | ASTM D570 | 0.40 % |
| Melt Volume Flow Rate (MVR) | 275°C/2.16kg | ISO 1133 | 20.0 cm3/10min |
| density | ISO 1183 | 1.47 g/cm³ | |
| ASTM D792 | 1.47 g/cm³ | ||
| Water absorption rate | Saturation,23°C | ISO 62 | 0.40 % |
| Equilibrium,50%RH | ASTM D570 | 0.20 % | |
| Equilibrium,23°C,50%RH | ISO 62 | 0.20 % | |
| Viscosity value | 降低的粘度 | ISO 1628 | 105.0 ml/g |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | ASTM D257 | 1E+14 ohms | |
| IEC 60093 | 1E+14 ohms | ||
| Volume resistivity | 1.50mm | ASTM D257 | >1.0E+13 ohms·cm |
| IEC 60093 | >1.0E+13 ohms·cm | ||
| Dielectric constant | 100Hz | IEC 60250 | 3.80 |
| 1MHz | IEC 60250 | 3.70 | |
| Dissipation factor | 100Hz | IEC 60250 | 3E-03 |
| 1MHz | IEC 60250 | 0.018 | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.