Impact strength of simply supported beam without notch
-40°C
kJ/m²
140
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
0.40mm
V-0 --
Basic Performance
Test Condition
Test Method
Test Result
Water absorption rate
(24hr)23°C
ASTM D-570
1.1 %
mechanical properties
Test Condition
Test Method
Test Result
tensile strength
23°C,Break
ASTM D-638
12 kg/cm
Ezo De Wei Sheng
Unnotched1/2" 23°C
5 kg.cm/cm
Tensile and flexural strength
23°C
ASTM D-638
850 kg/cm
bending strength
-40°C
ASTM D-790
1210 kg/cm
Bending modulus
-40°C
ASTM D-790
34500 kg/cm
tensile strength
23°C
MPa
85.0 65.0
tensile strength
80°C
MPa
45.0 --
Tensile strain
Break,23°C
%
7.5 7.5
Bending modulus
23°C
MPa
3500 1500
Bending modulus
80°C
MPa
1200 --
bending strength
-40°C
MPa
170 --
bending strength
23°C
MPa
125 70.0
bending strength
80°C
MPa
65.0 --
Taber abraser
1000Cycles
mg
9.00to10.0 --
thermal performance
Test Condition
Test Method
Test Result
Hot deformation temperature
4.6kg/cm
ASTM D-648
244 °C
Melting temperature
差示扫描测热计DSC法
265 °C
Hot deformation temperature
0.45MPa,Unannealed
°C
244 --
Melting temperature
°C
265 --
Melting temperature
265 ℃(℉)
Physical properties
Test Condition
Test Method
Test Result
Flame resistant grade
UL 94
113
Shrinkage rate
MD:1.00mm3
%
0.60-0.90
Shrinkage rate
MD:3.00mm4
%
1.0-1.6
Water absorption rate
23°C,24hr
%
1.1 --
Water absorption rate
Saturation,23°C
%
7.5 --
density
ASTM D792/ISO 1183
1.18
Electrical performance
Test Condition
Test Method
Test Result
Arc resistance
1/8"
ASTM D-150
127
Dielectric strength
1/8" 短时间
ASTM D-149
17 KV/mm
Volume resistivity
ASTM D-257
V-0 Ω.cm
Compared to the Leakage Traceability Index (CTI)
导热率温度指表
UL 746
600 V
Volume resistivity
ohms·cm
1E+15 --
Dielectric strength
kV/mm
28 --
Dielectric constant
23°C,50Hz
5.20 --
Dissipation factor
23°C,50Hz
0.070 --
Arc resistance
sec
127 --
Compared to the anti leakage trace index
CTI
V
PLC 0
hardness
Test Condition
Test Method
Test Result
Rockwell hardness
R-Sale,23°C
120 --
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.