PA66 Grilon® AS-V0 NC EMS-CHEMIE SWITZERLAND
252
- Unit Price:US$ 4,753 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:23MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High hardness|High temperature resistance
- Application Areas:Industrial machinery|Household daily necessities
- Color:--
- Grade:Flame retardant grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 65 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| ISO Type | ISO 1874 | PA 66. MFHR. 14-040 | |
| Extreme Oxygen Index | ISO 4589-2 | 32 % | |
| Flammability level | UL 94 | V-0 | |
| UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 3900 Mpa | |
| tensile strength | Yield | ISO 527-2 | 90.0 Mpa |
| Break | ISO 527-2 | 80.0 Mpa | |
| Tensile strain | Yield | ISO 527-2 | 4.0 % |
| Nominal tensile fracture strain | ISO 527-2 | 9.0 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 9.0E-5 cm/cm/°C |
| Flow | ISO 11359-2 | 6.0E-5 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 260 °C | |
| Continuous use temperature | --4 | Internal Method | 200 °C |
| --3 | ISO 2578 | 90.0 to 110 °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 75.0 °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 225 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.1 % |
| Flow | ISO 294-4 | 0.90 % | |
| Water absorption rate | Saturation, 23°C | ISO 62 | 7.0 % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 2.0 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Dissipation factor | 1 MHz | IEC 60250 | 0.020 |
| 100 Hz | IEC 60250 | 3.0E-3 | |
| Relative permittivity | 1 MHz | IEC 60250 | 4.00 |
| 100 Hz | IEC 60250 | 3.00 | |
| Dielectric strength | IEC 60243-1 | 31 KV/mm | |
| Volume resistivity | IEC 60093 | 1.0E+14 ohms·cm | |
| Surface resistivity | IEC 60093 | -- ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.