Impact strength of simply supported beam without notch
23°C
ISO 179
22 kJ/m²
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
0.73mm
UL 94
V-0
mechanical properties
Test Condition
Test Method
Test Result
tensile strength
Yield,23°C
ISO 527-2
155 Mpa
Tensile strain
Break,23°C
ISO 527-2
1.0 %
Bending modulus
23°C
ISO 178
20000 Mpa
bending strength
23°C
ISO 178
245 Mpa
shear strength
23°C
JISK7214
60.0 Mpa
Friction coefficient
0.30
Taber abraser
1000Cycles
ISO 9352
70.0 mg
Charpy Notched Impact Strength
ASTM D256/ISO 179
9 kg·cm/cm(J/M)ft·lb/in
Charpy Notched Impact Strength
ASTM D256/ISO 179
22 kg·cm/cm(J/M)ft·lb/in
Elongation at Break
ASTM D638/ISO 527
1 %
tensile strength
ASTM D638/ISO 527
95 kg/cm²(MPa)[Lb/in²]
Rockwell hardness
ASTM D785
123
Bending modulus
ASTM D790/ISO 178
20 kg/cm²(MPa)[Lb/in²]
bending strength
ASTM D790/ISO 178
245 kg/cm²(MPa)[Lb/in²]
thermal performance
Test Condition
Test Method
Test Result
Hot deformation temperature
1.8MPa,Unannealed
ISO 75-2/A
260 °C
Melting temperature
ISO 11357-3
278 °C
Linear coefficient of thermal expansion
MD
ISO 11359-2
1.8E-05 cm/cm/°C
Linear coefficient of thermal expansion
TD
ISO 11359-2
2.7E-05 cm/cm/°C
Combustibility (rate)
UL 94
V-0
Hot deformation temperature
HDT
ASTM D648/ISO 75
>260 ℃(℉)
Melting temperature
278 ℃(℉)
Linear coefficient of thermal expansion
ASTM D696/ISO 11359
1.8 mm/mm.℃
Physical properties
Test Condition
Test Method
Test Result
Shrinkage rate
TD:3.00mm2
Internal Method
0.60 %
Shrinkage rate
MD:3.00mm4
Internal Method
0.20 %
Water absorption rate
23°C,24hr
ISO 62
0.020 %
density
ASTM D792/ISO 1183
1.96
Shrinkage rate
ASTM D955
0.2 %
Water absorption rate
ASTM D570/ISO 62
0.02 %
Electrical performance
Test Condition
Test Method
Test Result
Volume resistivity
IEC 60093
1E+16 ohms·cm
Dielectric strength
IEC 60243-1
22 KV/mm
Dielectric constant
23°C,1MHz
IEC 60250
4.90
Dissipation factor
23°C,1MHz
IEC 60250
2E-03
hardness
Test Condition
Test Method
Test Result
Rockwell hardness
R-Scale
ISO 2039-2
123
Supplementary Information
Test Condition
Test Method
Test Result
BarFlowLength
320°C,1.00mm
Internal Method
110 mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.