PBT DURANEX® 313RA ED3002 JAPAN POLYPLASTIC
112
- Unit Price:US$ 2,795 /MT
- Packaging Specification:
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Good adhesion|15%GF|Filler: Glass fiber reinforced material|15% filler by weight
- Application Areas:--
- Color:--
- Grade:Enhanced level
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | ISO 527-1/-2 | 110 Mpa | |
| bending strength | ISO 178 | 160 Mpa | |
| Bending modulus | ISO 178 | 5330 Mpa | |
| Charpy Notched Impact Strength | ISO 179/1eA | 6.0 KJ/m | |
| tensile strength | ISO 527-2 | 110 Mpa | |
| Tensile strain | Break | ISO 527-2 | 3.0 % |
| Bending modulus | ISO 178 | 5330 Mpa | |
| bending strength | ISO 178 | 160 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8Mpa | ISO 75-1/-2 | 197 °C |
| UL flame retardant rating | UL 94 | HB | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 197 °C |
| Linear coefficient of thermal expansion | MD:23to55°C | Internal Method | 4E-05 cm/cm/°C |
| TD:23to55°C | Internal Method | 1E-04 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23°C,24hr | ISO 62 | 0.20 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | IEC 60093 | 2×10 Ω.cm | |
| Surface resistivity | IEC 60093 | 2×10 Ω | |
| Volume resistivity | IEC 60093 | 2E+16 ohms·cm | |
| Dielectric strength | 3.00mm | IEC 60243-1 | 24 KV/mm |
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 |
| Supplementary Information | Test Condition | Test Method | Test Result |
|---|---|---|---|
| ColourNumber | EF2001/ED3002 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.